285
17. Gateway Function
Associated
285
(1) Status display
The following status items are displayed.
No.
Indication
Description
1 Can't cont alm
Continuation unavailable alarm issued
2 Pos complete
Positioning completion
3 Home complete
Home return completion
4 Moving
Moving
5 Srv ON stat
Servo ON status
6 Ctrl ready
Controller ready
7 Push fault
Pushing failure
8 Emg stop stat
Emergency stop status
9 Btry vol low st
Battery voltage low status
10 Safe vel effect
Safety velocity effective status
11 Teach mode stat
Teach mode Status
12 Pos.zone
Position Zone
13 Zone1
Zone 1
14 Zone2
Zone 2
15 System Rsv 14
(System Reservation)
16 System Rsv 15
(System Reservation)
17 System Rsv 16
(System Reservation)
18 System Rsv 17
(System Reservation)
17.2. RC Actuator Monitoring
The RC actuator’s status, current position and alarm code are displayed.
RC Actuator Monitor Mode Change: RC - Moni - Stat
Select the RC actuator using the ten-key or
key.
Axis No.
Status display
Current Position/Alarm Code Display
When the (AClr) key is pressed, the mode is
transferred to the RC alarm reset mode.