![IAI SEL Instruction Manual Download Page 292](http://html1.mh-extra.com/html/iai/sel/sel_instruction-manual_604057292.webp)
274
17. Gateway Function
Associated
274
②
Inching Operation
Perform the RC actuator inching operation.
The actuator applicable to this operation is one with a single axis.
Place the cursor on the Axis No. and select the RC actuator using the ten-key or
.
Current Position
Servo ON
Press the key (Inc).
Set the inching distance (travel distance for each
pressing of the JOG key).
Input the value in the “Dis” (inching distance) data box.
The numerical value input range is from 0.00 to
1.00 (Unit: mm).
* When “0.00” is input, the jogging operation is
performed. When “0.01” or more is input, the
inching operation is performed.
Press the key.
Turn the servo-motor ON.
The status of servo-motor ON/OFF is confirmed in
the Axis Status Display Section (When “S” is displayed,
the servo-motor is turned ON and it is not displayed,
the servo-motor is turned OFF).
Press the or key to move the actuator to any
position. (“+” means the movement to the plus
direction on the coordinates and “-“means the
movement to the minus direction on the coordinates).