![IAI SEL Instruction Manual Download Page 243](http://html1.mh-extra.com/html/iai/sel/sel_instruction-manual_604057243.webp)
16. Controller
225
208
* If case (1)
①
and (2)
①
occur at the same time, you need to first execute Driver Power
Recovery Request. After completing it, execute the Action Pause Release Request.
18
.
12. Selection of Two or More Programs Start Prohibition/Permission
Sets whether to permit or prohibit the simultaneous starting of multiple programs in the manual
mode.
If prohibition is set, multiple programs will not be able to be started simultaneously. (Error no. 913
“Can’t start two or more programs” will occur.)
Select the F1 (MTsk) key on the controller screen.
Mode Transition: Ctl–MTsk
* This function is valid only for the following models:
▪
X-SEL-P/Q (main application Ver. 0.36 or later)
▪
X-SEL-PX/QX (main application Ver. 0.17 or later)
▪
SSEL, ASEL, PSEL (main application Ver. 0.01 or later) (*only in the program mode)
To permit the simultaneous starting of multiple
programs, press “0.” To prohibit it, press the [X] key.
Then, press the F1 (OK) key.
To cancel the setting, press the F2 (Canc) key.
If the F1 (OK) key is pressed and executed on the
previous screen, this screen will be displayed.
To execute the setting, press the F4 (AStp) key.
To cancel the setting, press the ESC key.
Note: To set prohibition, it is required to exit all the
program execution.
16.12.
• XSEL-R/S, RX/SX, RXD/SXD
• SSEL, ASEL, PSEL (main application Ver. 0.01 or later) (*only in the program mode)