1.2 Specifications
1-30
1. Specifications
3) Read a reference for duty with the figured out “Load Factor” and “Acceleration /
Deceleration Time Ratio”.
e.g.) The reference for duty when the load factor LF is 80% and the acceleration / deceleration time
ratio t
od
is 80% should be approximately 75%.
0
20
40
60
80
100
0
20
40
60
80
100
加減速度時間比率
t
o
d
〔
%
〕
デュ
ー
ティ
ー
の
目安〔
%
〕
LF
= 60%
LF = 50%
未満
約
75%
LF
LF
LF
LF
= 70%
= 80%
= 90%
= 100%
負
荷率〔
%
〕
Reference fo
r Du
ty [%]
Acceleration / Deceleration Time Ratio t
od
[%]
LF
= Below 50%
Load Factor
[%]
Approximately 75%