background image

100mm or more

10mm

or more

10

0mm o

r mor

e

50m

m o

r mor

e

Ceiling

REC System

Ceiling

10mm

or more

Earth Terminal 
Grounding resistance at 100Ω or less 
(Class D grounding) 

(2) EC Connection Unit 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Front 

 

1. EC Gateway Unit 

Item 

Specification 

External Dimensions 

30W × 115H × 95D [mm] 

Mass 

Approx. 135g 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

2. EC Connection Unit 

Item 

Specification 

External Dimensions 

22.6W × 115H × 95D [mm] 

Mass 

Approx. 114g 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3. REC Terminal Unit 

Item 

Specification 

External Dimensions 

12.6W × 115H × 95D [mm]

 

Mass 

Approx. 48g 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. Linking Units 

Item 

Specification 

External Dimensions 

(42.6 + 22.6 × N) W × 115H × 95D [mm]    N: Total number of EC Connection Units 

Mass 

Approx. (183 + 114 × N) g    N: Number of EC Connection Units 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Installation Environment 

This product is capable for use in the environment of pollution degree 2 

*1

 or equivalent. 

*1  Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive 

pollution by frost (IEC60664-1) 

1.  Installation Environment 

Do not use this product in the following environment. 

  Location where the ambient temperature is out of the range between 0 and 55

°

  Location where condensation occurs due to abrupt temperature changes 

  Location where relative humidity exceeds 85%RH 

  Location exposed to corrosive gases or combustible gases 

  Location exposed to significant amount of dust, salt or iron powder 

  Location subject to direct vibration or impact 

  Location exposed to direct sunlight 

  Location where the product may come in contact with water, oil or chemical droplets 

  Environment that blocks the air vent [Refer to Installation and Noise Elimination] 

When using the product in any of the locations specified below, provide a sufficient shield. 

  Location subject to electrostatic noise 

  Location where high electrical or magnetic field is present 

  Location with the mains or power lines passing nearby 

2.  Storage and Preservation Environment 

The storage and preservation environment should comply with the same standards as those for the 
installation environment. 
In particular, when the machine is to be stored for a long time, pay close attention to environmental 
conditions so that no condensation forms. Unless specially specified, moisture absorbency protection is not 
included in the package when the machine is delivered. In the case that the machine is to be stored and 
preserved in an environment where condensation is anticipated, take the condensation preventive 
measures from outside of the entire package, or directly after opening the package. 
 

 

Installation and Noise Elimination 

1.  Noise Elimination Grounding (Frame Ground) 

 
 
 
 
 
 
 
 
 
 

 

2.  Precautions regarding wiring method 

1)  Wire is to be twisted for the 24V DC power supply. 
2)  Separate the signal and encoder lines from the power   

supply and power lines. 

 

3.  Noise Sources and Elimination 

Carry out noise elimination measures for electrical devices   
on the same power path and in the same equipment. 
The following are examples of measures to eliminate noise   
sources. 
1)  AC solenoid valves, magnet switches and relays 

[Measure]  Install a Surge absorber parallel with the coil. 

2)  DC solenoid valves, magnet switches and relays 

[Measure]  Consider whether to attach a diode in parallel   

to the coil or to use a diode built-in type. 

4.  Cooling Factors and Installation 

Follow the specifications and dimensions shown below when you design and build a control board. 

Item 

Specification 

 

Item

Specification

Installation 
Orientation 

Vertical Orientation   
(Air outlet upwards) 

 

Surrounding Air 
Temperature 

0 to 55

°

C   

Installation 
Method 

Attached on DIN Rails 

 

Installation 
Condition 

See figure below 

  Grounding 

Class D grounding 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Connection to Peripheral Devices (Overall Wiring Diagram)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

External Dimensions 

Do not share the ground wire with or connect 
to other equipment. Ground each controller.

Controller

Other 

equipment

Controller

Other 

equipment

Other 

equipment

Surge absorber

Relay 
coil

Relay coil

R

C

+24V

0V

+24V

0V

+

-

T RUN LED 

SYS LED 

Brake release switch (1 to 4 axis)

Model Plate 

(Large) 

Adhered 

Position 

Model Plate 

(Large) 

Adhered 

Position 

Field Network

(Cables to be prepared

 by customer)

USB Cable

(Cables to be

 prepared by

 customer)

Power Supply Cable

(Cables to be prepared by

  customer)

* Use cable with diameter

   large enough to accept

   current.

EC Connection Unit Cable
  Standard Connector Model Code:

CB-REC-PWBIO□□□(-RB)

 Four-Way Connector Model Code:

CB-REC2-PWBIO□□□(-RB)

ELECYLINDER

PC

TB-02/TB-03

(to be purchased

separately)

PSA-24

Master Unit

(Cables to be prepared

 by customer)

PC Software

(to be purchased

separately)

Connector for EC Connection (1st axis) 

Connector for EC Connection (2nd axis) 

Connector for EC Connection (3rd axis) 

Connector for EC Connection (4th axis) 

Backward End LED

 

(1 to 4 axis) 

JOG Switch (1 to 4 axis) 

Forward End LED

 

(1 to 4 axis) 

Drive Source Cutoff Connector 

N

4

Summary of Contents for REC-GW

Page 1: ... what is after UL CE acquired 1 EC Gateway Unit 2 EC Connection Unit Mark Explanation of Mark Use IAI specified cables only 5 How to read the model code 1 EC Gateway Unit 2 EC Connection Unit 3 ELECYLINDER ELECYLINDER available for connection to REC System is only Option ACR 1 Specifications of Power Supply Item Specification Power Input Voltage Range 24V DC 10 Supply Current Described in Current ...

Page 2: ...hine is to be stored and preserved in an environment where condensation is anticipated take the condensation preventive measures from outside of the entire package or directly after opening the package Installation and Noise Elimination 1 Noise Elimination Grounding Frame Ground 2 Precautions regarding wiring method 1 Wire is to be twisted for the 24V DC power supply 2 Separate the signal and enco...

Page 3: ...at the left end as the interface for the field network connection and freely construct with combination of multiple EC Connection Units There is an order of allocation for each unit EC Gateway Unit Left End EC Connection Unit No Order among REC Terminal Unit Right End Each unit should be linked in the process shown below Make sure it gets linked before connected to the DIN rails 1 Twist the operat...

Page 4: ...ating Inside bus communication in normal conditions Flashing Waiting for initializing communication Initializing communication failed OR Illuminating Inside bus communication in error SYS GN Illuminating Servo ON OFF Servo OFF RD Illuminating Alarm being generated stop switch on teaching pendant valid while pressed and held Forward End GN Illuminating Movement to forward end completed OFF Stop RD ...

Page 5: ...Flashing Malfunction with opportunity for recovery STATUS 1 NS GN Illuminating Online connection established Flashing Online No connection established OR Illuminating Critical error IP address duplicated error Flashing Connection Timeout GN OR OFF No IP address 6 PROFIBUS DP REC GW PR Name Panel Display Color Status Explanation STATUS 0 MS GN Illuminating Initialization completed Flashing Initiali...