100mm or more
10mm
or more
10
0mm o
r mor
e
50m
m o
r mor
e
Ceiling
REC System
Ceiling
10mm
or more
Earth Terminal
Grounding resistance at 100Ω or less
(Class D grounding)
(2) EC Connection Unit
Front
1. EC Gateway Unit
Item
Specification
External Dimensions
30W × 115H × 95D [mm]
Mass
Approx. 135g
2. EC Connection Unit
Item
Specification
External Dimensions
22.6W × 115H × 95D [mm]
Mass
Approx. 114g
3. REC Terminal Unit
Item
Specification
External Dimensions
12.6W × 115H × 95D [mm]
Mass
Approx. 48g
4. Linking Units
Item
Specification
External Dimensions
(42.6 + 22.6 × N) W × 115H × 95D [mm] N: Total number of EC Connection Units
Mass
Approx. (183 + 114 × N) g N: Number of EC Connection Units
Installation Environment
This product is capable for use in the environment of pollution degree 2
*1
or equivalent.
*1 Pollution Degree 2: Environment that may cause non-conductive pollution or transient conductive
pollution by frost (IEC60664-1)
1. Installation Environment
Do not use this product in the following environment.
•
Location where the ambient temperature is out of the range between 0 and 55
°
C
•
Location where condensation occurs due to abrupt temperature changes
•
Location where relative humidity exceeds 85%RH
•
Location exposed to corrosive gases or combustible gases
•
Location exposed to significant amount of dust, salt or iron powder
•
Location subject to direct vibration or impact
•
Location exposed to direct sunlight
•
Location where the product may come in contact with water, oil or chemical droplets
•
Environment that blocks the air vent [Refer to Installation and Noise Elimination]
When using the product in any of the locations specified below, provide a sufficient shield.
•
Location subject to electrostatic noise
•
Location where high electrical or magnetic field is present
•
Location with the mains or power lines passing nearby
2. Storage and Preservation Environment
The storage and preservation environment should comply with the same standards as those for the
installation environment.
In particular, when the machine is to be stored for a long time, pay close attention to environmental
conditions so that no condensation forms. Unless specially specified, moisture absorbency protection is not
included in the package when the machine is delivered. In the case that the machine is to be stored and
preserved in an environment where condensation is anticipated, take the condensation preventive
measures from outside of the entire package, or directly after opening the package.
Installation and Noise Elimination
1. Noise Elimination Grounding (Frame Ground)
2. Precautions regarding wiring method
1) Wire is to be twisted for the 24V DC power supply.
2) Separate the signal and encoder lines from the power
supply and power lines.
3. Noise Sources and Elimination
Carry out noise elimination measures for electrical devices
on the same power path and in the same equipment.
The following are examples of measures to eliminate noise
sources.
1) AC solenoid valves, magnet switches and relays
[Measure] Install a Surge absorber parallel with the coil.
2) DC solenoid valves, magnet switches and relays
[Measure] Consider whether to attach a diode in parallel
to the coil or to use a diode built-in type.
4. Cooling Factors and Installation
Follow the specifications and dimensions shown below when you design and build a control board.
Item
Specification
Item
Specification
Installation
Orientation
Vertical Orientation
(Air outlet upwards)
Surrounding Air
Temperature
0 to 55
°
C
Installation
Method
Attached on DIN Rails
Installation
Condition
See figure below
Grounding
Class D grounding
Connection to Peripheral Devices (Overall Wiring Diagram)
External Dimensions
Do not share the ground wire with or connect
to other equipment. Ground each controller.
Controller
Other
equipment
Controller
Other
equipment
Other
equipment
Surge absorber
Relay
coil
Relay coil
R
C
+24V
0V
+24V
0V
+
-
T RUN LED
SYS LED
Brake release switch (1 to 4 axis)
Model Plate
(Large)
Adhered
Position
Model Plate
(Large)
Adhered
Position
Field Network
(Cables to be prepared
by customer)
USB Cable
(Cables to be
prepared by
customer)
Power Supply Cable
(Cables to be prepared by
customer)
* Use cable with diameter
large enough to accept
current.
EC Connection Unit Cable
Standard Connector Model Code:
CB-REC-PWBIO□□□(-RB)
Four-Way Connector Model Code:
CB-REC2-PWBIO□□□(-RB)
ELECYLINDER
PC
TB-02/TB-03
(to be purchased
separately)
PSA-24
Master Unit
(Cables to be prepared
by customer)
PC Software
(to be purchased
separately)
Connector for EC Connection (1st axis)
Connector for EC Connection (2nd axis)
Connector for EC Connection (3rd axis)
Connector for EC Connection (4th axis)
Backward End LED
(1 to 4 axis)
JOG Switch (1 to 4 axis)
Forward End LED
(1 to 4 axis)
Drive Source Cutoff Connector
(
N
=
4
)