LQ-401CL
53
7.38 Command TR – Trigger Mode
Selects the trigger mode of the camera. Depending on the mode used, it allows the scan rate to
either be programmed by an internal timing generator or by and external trigger pulse. See chapter
6 for details on the operation modes.
Settings:
0=No-shutter mode
1=Shutter-Select mode
2=Pulse Width Control (PWC) mode
Associated functions:
Command TG (trigger origin)
Command TI (trigger input)
Command TP (trigger polarity)
7.39 Command TS – Test Pattern
This allows the camera to output a number of test patterns for set-up and troubleshooting.
Settings:
0=off
1=Color bar
2=Gray wedge
3=Gray bars
4=White (890LSB)
7.40 Command WB – White Balance
The white balance function can be used for manual setting, one-push automatic white balance
(AWB) and fixed color temperatures (3 selections)
Settings:
0=Manual / On-Push AWB
1=4000K
2=4600K
3=5600K
Applicable modes:
All
Associated functions:
Command AW (Gain)
Command AH (Shutter)
Command GAR – Gain Level red channel
Command GAB – Gain Level blue channel