LQ-401CL
29
6.3.1 Camera Default Settings
The following table shows the default settings of LQ-401CL
Item
Default setting
Value
Gain
Master mode B/G/R/NIR
0dB
Black
Master mode B/G/R/NIR
8LSB
Trigger Mode
No-shutter
Trigger Origin
Internal
Auto Reset Mode
ON
Input
Camera Link
Polarity
Active Low
Line Rate
24000
Bit Allocation
8-bit
Binning
OFF
Test Pattern
OFF
Noise Reduction
OFF
6.3.2 No-Shutter mode with Internal Trigger
In this mode, the exposure and readout are activated by the trigger pulse generated internally.
As the accumulation control is done by the internal counter, the accumulation is not affected by the
trigger jitter.
In this mode, the accumulation period depends on the trigger interval. Accordingly, if trigger
interval becomes longer, the sensitivity is increased.
To use this mode:
Set function
Trigger mode, No-Shutter
TR=0
Trigger origin, Internal
TG=0
Line rate
LR=4602 to 1201920
(54.70 µs to 14.30 ms in 11.9 ns increments)
Optional functions when using this mode:
One-push auto line rate
AR=0
Auto line rate reference
AL=0 to 1023
One-push white balance
WB
Important Note
The “one-push auto line rate” function is not recommended for continuous web applications, as
the speed of motion needs to be adjustable in order to maintain the aspect ratio of the image.
Only gain based one-push white balance functions (WB) are available with this mode.