4.4 I/O signals
4-12
4. Operation
[ST0] [ST1] signals: Movement command input (backward/forward)
The ST signal function automatically switches depending on whether the unit has completed
home return or not.
Signal name
Signal
abbreviation
Function overview by status
Home return:
Not complete
Home return: Complete
Backward
ST0
Home return operation
Backward
Forward
ST1
Forward
[Home return status: Not complete]
● When the [ST0] signal is turned ON, home return operation begins.
● When the [ST1] signal is turned ON, as with the [ST0] signal, home return operation begins.
● Turning the ST signal OFF midway through home return operation will cause a gradual stop.
[Home return status: complete]
● When the ST signal is turned ON, the ELECYLINDER moves [Backward] and [Forward].
● While the ST signal is ON, operation will continue until the [Backward end] or [Forward end]
is reached.
● Turning the ST signal OFF midway through operation will cause a gradual stop.
→ For details, refer to "4.5 Operating method from master device".
Caution
If stopped when the LS or PE signals are not ON, the ELECYLINDER may be stopped
on the way to the backward or forward end, or it may have stopped at the backward or
forward end during pressing operation with no contact.
We recommend first inputting the [ST0] signal and then performing the following actions
after returning to the backward end.
If battery-less absolute specification (option) is selected, the home return complete
status is retained.
However, if the [Change home return direction] or [Adjust home position] parameters
are changed, home return status will be not-complete; perform homing (absolute reset).
→ For details, refer to "6.4 Parameter function descriptions".
Summary of Contents for EC-ST15
Page 2: ......
Page 26: ...Intro 18 ...
Page 28: ......
Page 44: ......
Page 60: ...2 16 2 Installation ...
Page 62: ......
Page 82: ...3 20 3 Wiring ...
Page 106: ......
Page 112: ...5 6 5 Preventive Predictive Maintenance ...
Page 114: ......
Page 128: ...6 14 6 Parameters ...
Page 130: ......
Page 148: ...7 18 7 Troubleshooting ...
Page 150: ......
Page 190: ...8 40 8 Maintenance and Inspection ...
Page 192: ......
Page 194: ...9 2 9 External Dimensions ...
Page 196: ......
Page 198: ...10 2 10 Life ...
Page 200: ......
Page 203: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 204: ......
Page 209: ......