4.3 Stop position/operating conditions (AVD) setting/adjustment
4-10
4. Operation
Touch the [Pressing force] and [Press starting point] buttons.
Ten Key window will open.
After setting the numerical value, touch the [ENT] key.
The screen will switch to the Simple Data Setting window.
Touch the [Transfer] key.
The numerical values will
be written to the controller.
The [B. End] button and
[F. End]
button will
turn green.
Press the [F. End] or [B. End] buttons to operate.
Check the results of the new setting/adjustment.