![IAI EC-ST15 Instruction Manual Download Page 93](http://html.mh-extra.com/html/iai/ec-st15/ec-st15_instruction-manual_603971093.webp)
4.3 Stop position/operating conditions (AVD) setting/adjustment
4-9
4. Operation
Pressing operation setting
Setting item
Unit
Explanation
Pressing
starting point
mm
The position where pressing operation starts.
Enter as the distance from the home position.
Entries can be made in increments of 0.01mm.
Pressing
force
%
or
N
The current limit value during the pressing operation.
Set between 30 and 70%.
[Switch units] can be used to input values in N units.
The pressing speed is 20 mm/s.
If [V: Velocity] is set to 20mm/s or below, pressing will
take place at the speed of [V: Velocity].
Caution
The pressing force displayed in N units serves as a guideline.
→ Refer to "Pressing force and current limit value relationship" on pages 1-8.
When the pressing speed is 20mm/s or less, the pressing force will become unstable,
and failure to operate normally is possible.
Check [Press].
The screen will switch to
the pressing operation
window.
Action
1
Summary of Contents for EC-ST15
Page 2: ......
Page 26: ...Intro 18 ...
Page 28: ......
Page 44: ......
Page 60: ...2 16 2 Installation ...
Page 62: ......
Page 82: ...3 20 3 Wiring ...
Page 106: ......
Page 112: ...5 6 5 Preventive Predictive Maintenance ...
Page 114: ......
Page 128: ...6 14 6 Parameters ...
Page 130: ......
Page 148: ...7 18 7 Troubleshooting ...
Page 150: ......
Page 190: ...8 40 8 Maintenance and Inspection ...
Page 192: ......
Page 194: ...9 2 9 External Dimensions ...
Page 196: ......
Page 198: ...10 2 10 Life ...
Page 200: ......
Page 203: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 4 ELECYLINDER Chapter12 ...
Page 204: ......
Page 209: ......