background image

transmission sources while searching.

 

 

2.3.2.2.3 

Sensitivity and vibrate-mode indication engagement threshold adjustment.

 

You will need to adjust the device sensitivity within the searching process (scale item 

6 in Fig.8) and 

(if 

needed) the vibrate-mode indication engagement threshold (scale item 

7 in Fig.8). 

To select the scale use 

 

and 

buttons (in order 

to confirm selection press and hold the button for 2 seconds, with that the selected 

scale marker will glow

and the adjustment is done by pressing the 

 

and 

 buttons. 

 

The sensitivity adjustment scale is active by default

You need to adjust the device sensitivity in the way 

that selected graph will not "go into overdrive"

The 

 button increases the sensitivity (to display signals 

that have a weaker amplitude)

The 

 button decreases sensitivity in order to display stronger signals.

 

The device supports automatic sensitivity adjustment. To perform this in the search mode, press and hold 

the 

 button for 2 seconds

Automatic adjustment is performed according to the average signal strength level 

(graph item 2 in Fig.8). 

Vibrate-mode indication engagement threshold adjustment is performed in accordance with the average

 

signal strength level, displayed in real time on the scale (item 7, Fig.8) in the device’s full dynamic range,

 

without a reference to selected sensitivity level. This scale can be used for the overall assessment of the radio 
environment at the current moment. 

 

2.3.2.2.4 Scanning adjustment.

 

The graph items 1 and 2 of Fig. 8 display radio environment changes during the last 7.5 seconds by default. 

This time interval can be increased or decreased if necessary. Available values are as follows

: 2.5 sec.; 4.5 sec.; 

7.5 sec.; 12 sec. and 22 sec. Scanning adjustment 

is performed by short-pressing the buttons 

 and 

. After 

switching, the current 

scanning 

value is briefly displayed in the lower left corner of the screen.

 

 

 

2.3.2.2.5 Measurement channel selection.

 

Measurement channel selection (ANT1, ANT2, ANT1+ANT2) is performed by successively pressing the 

button 

. The icons of the selected measurement channels in the upper part of the screen are highlighted. 

The channel ANT1 is more sensitive and is suitable for searching the vast majority of bugs and other radio 
transmitting devices, including analog radio microphones and devices based on cellular radio modules, etc. 
The measurement channel  ANT2 is faster  and  of  higher  frequency.  First  of  all, it is  designed  to  search  for 
devices operating at 2.4 GHz and above (these can be Wi-Fi / Bluetooth 2.4/5 GHz modules, analog video 
cameras 5.8 GHz and other modern devices).

 

 

Note. 

1. For express analysis, the measurement channels ANT1 and ANT2 can be shared, however, it should be 

noted that all capabilities of the high-sensitive channel ANT1 will not be used in this case, since product sen-
sitivity will be limited according to the characteristics of the channel ANT2. 

 

2. The advantage of channel ANT2 is high speed (response to nanosecond pulses) and operation in the 

microwave range of up to 8 GHz. At the same time, it is also applicable to searching for transmitters with a 
lower operating frequency than 2.4 GHz, both digital and analog, but less sensitive than the channel ANT1, 
and therefore less suitable when searching for low-power (microwatt) analog transmitters. 

 

2.3.2.2.6 Use of sound indication.

 

The acoustic control function is provided in the Product - the demodulated sound signal is output through 

the built-in speaker. The sound volume can be adjusted with the help of buttons (item 9 Fig. 2). For hidden 
control, the volume can be lowered to a zero level or headphones can be used. 

 

Summary of Contents for BugHunter Professional BH-04

Page 1: ...RF signal detector BugHunter Professional BH 04 User manual...

Page 2: ...1 Application area 1 2 Technical features 1 3 Device components 1 4 Internal design and operation 2 Intended use 2 1 Operating restrictions 2 2 Before operating 2 3 Intended usage 3 Technical mainten...

Page 3: ...anual carefully in order to provide continuous successful and safe operation of the pur chased Product Follow the rules restrictions and instructions contained in this manual to increase the lifespan...

Page 4: ...rance is shown in Fig 1 Fig 1 The Product appearance 1 2 Technical features Table 1 Description Value Dimensions mm not more than without receiving antennas 130 80 16 mm 5 12x3 15x0 63 in Weight 0 2 k...

Page 5: ...power supply There are electronic mod ules and a battery inside of the case item 1 which are made of aluminum alloy The product has a TFT display item 2 mini USB connector item 3 for the charger and...

Page 6: ...m of a signal s level change graph on the time curve allows users to identify the nature of the signal and the type of transmitter For more convenient localization of transmitting devices and informat...

Page 7: ...The device always starts with the Search mode The icon of the adjusted mode is displayed in the top bar of the screen Search mode Oscilloscope mode Security mode You can switch between operating modes...

Page 8: ...2 1 Graphical presentation of information in the Search mode Search mode is the main operating mode used to search for radio transmitting devices indoors The main elements of the search mode s graphic...

Page 9: ...ak and average radio signal strength cl 2 3 2 2 8 Subtracting background On the right part of the screen the scales for adjusting the sensitivity item 6 and the selection of the vibration engagement t...

Page 10: ...2 sec Scanning adjustment is performed by short pressing the buttons and After switching the current scanning value is briefly displayed in the lower left corner of the screen 2 3 2 2 5 Measurement ch...

Page 11: ...in cases can break the connection or deactivate the bug remotely making further searching senseless Therefore do not discuss your actions out loud and use the probing signal function with caution Prep...

Page 12: ...ge values as shown in Fig 10 then there is a high probability of an operating digital transmitter The digital character of the de tected signal is also defined by obvious transmission pause intervals...

Page 13: ...scan is displayed in the lower left corner of the screen for a short time 2 3 2 3 4 Oscillogram freezing and unfreezing You can stop the signal rendering on a screen for a detailed signal form analysi...

Page 14: ...Note 1 The opportunity to adjust the device is limited in Security mode To make adjustments vibration intensity registered alarm events etc you need to switch the device to the Search mode or Oscillos...

Page 15: ...ed brightness level by pressing and Press to save settings and return to the main menu To exit without saving press 2 3 3 4 Vibration level adjustment Being in the main menu Fig 13 select Vibration by...

Page 16: ...e threshold signal level 10 dB by default then press the button The numerical value selection in dB will be activated as shown in Fig 19 Fig 19 Relative threshold signal level change for alarm engagem...

Page 17: ...nge the time interval 5 sec by default then press the button Numerical value selection will be activated in seconds as shown in Fig 21 Fig 21 Minimum alarm duration setting Select the necessary value...

Page 18: ...menu in order to continue adjustment or they can exit to the operation mode by pressing Note In the Security mode this setting is ignored 2 3 4 Connection to PC When connected to a PC over the curren...

Page 19: ...and mechanical damage 3 3 Recharge batteries regularly The power level is indicated by the filling level and the color of the battery sign located in the top bar of the screen 3 4 You should charge th...

Page 20: ...sport in pressurized modules During transportation the packaged products should be protected from the direct impact of atmospheric condensation and solar radiation Transportation terms Environmental t...