![i-PRO WJ-NX400K/G Operating Instructions Manual Download Page 37](http://html2.mh-extra.com/html/i-pro/wj-nx400k-g/wj-nx400k-g_operating-instructions-manual_3059995037.webp)
37
[Display the schedule list.]
Display each time table from Schedule 1 to Schedule
16 and settings of the schedule recording, event
recording, etc. The schedule list will be displayed
when clicking [View] button.
Time zones from 1 to 6 of each time table are super-
imposed and displayed.
[Back] button
Click the button after completing the settings. The
screen returns to the [Recording setup] tab.
Manual: Recording will continue while receiving
an alarm input signal. Recording will be per-
formed for at least 8 seconds.
Ext.: Alarm output will continue until the alarm
action is reset. Refer to the "Cancel the alarm
action" (
☞
Page 129) for further information
about how to cancel the alarm action.
Default:
30 s
[Pre-event duration]
Set the recording duration before an alarm occurs.
0 s/ 5 s/ 10 s/ 15 s
Default:
0 s
Important:
• The pre-event recording is only available for Camera
1 to Camera 64.
• The pre-event recording available time becomes
extremely short when the sub-stream recording is on.
• The pre-event recording is available for Camera 1 to
Camera 128 at the additional camera (96ch/128ch)
mode.
Note:
• The actual recording time may sometimes be
longer than the duration selected for this setting.
• When the sub-stream recording is "Off" in the
64ch mode, the pre-event duration of cameras up
to 31ch differs from that of 32ch and higher.
• Pre-event recording is not performed when "0 s"
is selected.
• When images are set to be recorded together with
audio, the audio may not be recorded at the
beginning of the pre-event recording.
■
Schedule to record
Two time tables can be set.
[Schedule recording] (
☞
[Event recording] (
☞
[e-Mail] (
☞
[TCP alarm notification] (
☞
[Prev page] / [Next page]
The schedule settings to be configured will be
switched over.
[Setup via recorder's main monitor]