CLEANING
AND
MAINTENANCE
CAUTION
:
THE
MACHINE
SHOULD
NOT
BE
CLEAN ED
BY
WATER
JET
1.
Cleaning schedule
After
each
use
Daily
on
completion
of
service
Once
a
week
Steam Tube
X
( automatic purge)
Barista
Steam
X
(automatic
purge)
x
Brewheads
x
Filter holder
x
Drip tray
x
Evacuation
dish
x
Bodywork
x
2. Cleaning procedures
Coffee brewhead
Reneka cleaning kit,
ref
9003479
:
Designed to ease and improve the daily upkeep of your reneka machine to enable you to make better
coffees. The cleaning kit comes with the following accessories:
A rubber obturator.
A box of 100 reneka tablets
(reference
1011014).
A cleaning brush
Place the obturator in the
two-cup filter-holder and
add a reneka detergent
tablet.
Connect the filter-holder.
Hold down both buttons
simultaneously on the ends
to start the cleaning cycle. The
LEDs flash from left to right.
After a few minutes LEDS
flash and you need to
remove the obturator.
After switching the filter holder,
press any button for the
program rinses. The cleaning
cycle is automatically canceled.
Comment
:
The cleaning cycle can be run
independently
n each group or on all
the groups simultaneously.
The cleaning cycle, once
started, continues
to completion