“i-Kare” Intelligent Blood Pressure 

Monitor 

Model: iBP-130 / User Manual 

 

 

 

 

 

Be sure to read this instruction before you use the device. 

 

Ver.0.63 Issue date: 2017/07/28 

Summary of Contents for iBP-130

Page 1: ...i Kare Intelligent Blood Pressure Monitor Model iBP 130 User Manual Be sure to read this instruction before you use the device Ver 0 63 Issue date 2017 07 28...

Page 2: ...2 4 Fingerprint recognition 14 2 5 Delete fingerprint registration 14 3 Take a Measurement 15 3 1 Correct Posture 15 3 2 Applying the Arm Cuff 16 3 3 Take a Measurement 17 3 4 Manual Inflate Function...

Page 3: ...2 8 Main Functions 27 Appendix I 30 Appendix II 37 Appendix III 39...

Page 4: ...use as well as ambulance It is not suggested to be used in public space It is non invasive meaning no part of the monitor enters your body It provides systolic pressure diastolic pressure and pulse me...

Page 5: ...cal equipment Part 1 11 General requirements for basic safety and essential performance Collateral standard Requirements for medical electrical equipment and medical electrical systems used in the hom...

Page 6: ...City Taiwan R O C Tel 886 2 2218 0150 EU representative Manufacturer Type BF Applied part Biostar Microtech Netherlands BV Archimedesweg 2A 5928PP Venlo The Netherlands BIOSTAR MICROTECH INTERNATIONAL...

Page 7: ...esigned with a large LCD display as a result the elderly and visually impaired are able to read the measurements The monitor not only recognizes five users with their own fingerprints but also stores...

Page 8: ...the monitor and cuff with a dry soft cloth or a cloth dampened with water and a mild detergent Never use benzene thinner or other harsh chemicals to clean monitor or cuff Warning If you fold the arm c...

Page 9: ...8 Please be aware that the cuff and its pressurization may cause temporary intererence to blood flow and injury to the patient Disposal Follow the national requirement to dispose unit...

Page 10: ...9 1 Part Description Main Unit Power Menu Up Down LCD Display Battery Compartment Air Jack Start...

Page 11: ...Time Record Symbol Battery Indicator Body Motion Symbol Pumping Leaking Air Symbol Heartbeat Irregular heartbeat Symbol Pulse Diastolic Blood Pressure Systolic Blood Pressure Transmission Symbol Fing...

Page 12: ...as adaptor is acceptable After replacing the battery you may need to reset the time and date 4 new batteries allow users to measure your blood pressure for proximately 1000 times Please dispose the b...

Page 13: ...value 4 After setting Month press Menu to save the change and move to Date Now you shall see Date flashing on the display Please press Up or Down to change the value 5 Please press Menu to save the c...

Page 14: ...lect your user ID press Start to confirm it Then the first box of the bar is illuminated and please place your finger in the finger print receptor Remove your finger when the firs box of the bar is fl...

Page 15: ...t registration To recognize your fingerprint please turn on the monitor When symbol is illuminated place your registered finger in the finger print receptor Your user ID will be shown on the display 2...

Page 16: ...ft arm on a table and relax your arm as shown below To avoid errors please maintain the correct posture during the measurement Make sure the cuff is at your heart level When measuring blood pressure l...

Page 17: ...the figure below to apply the arm cuff correctly Fasten the arm cuff on the left upper arm and exhaust air out form arm cuff to avoid error The air tube should parallel with your arm and align the mar...

Page 18: ...nt When it is finished your measured value will appear on the display Please note if your registered finger is injured or you are unable to place it in the finger print receptor for any reasons you ma...

Page 19: ...flate mode before the cuff inflated to 180mmHg When cuff pressure reaches 290 mmHg the cuff will be deflating and measurement starts If you do not wish to inflate to 290mmHg you can release Up during...

Page 20: ...n on the display Press Menu once and wait for a second to enter Review Mode 1 The symbol will be shown on the display Now you may select your own record by pressing Up or Down 2 The display will show...

Page 21: ...20 4 If you wish to exit the Review Mode please press Power to exit Press Up or Down to select the records...

Page 22: ...monitor and press Menu once the symbol will be appeared on the display Then turn on APP and press It will then search Bluetooth from the monitor Once Bluetooth is detected the Bluetooth address will a...

Page 23: ...n the floor Do not spill the water on the main unit and cuff arm or immerse them in water Do not use volatile liquids to clean the main unit Cleaning the main unit with a soft dry cloth Use 75 alcohol...

Page 24: ...main unit incorrectly Insert the plug securely Refer to Applying the Arm Cuff Air is leaking from the arm cuff Replace the cuff with the new one The motor or deflating valve is fail Please contact di...

Page 25: ...use Correction E08 When systolic or diastolic pressure is over than 230 mmHg or is less than 40 mmHg Measure blood pressure with other device Batteries are worn out Replace new batteries Refer to Batt...

Page 26: ...f correctly Refer to Applying the Arm Cuff Air is leaking from the arm cuff Replace the cuff with the new one Sensor malfunction Please turn off the main unit and restart it Contact customer service f...

Page 27: ...ery x4 Time maintain function After time date setting the record will maintain for 4 hours without batteries Operating Temperature Humidity 10 to 40 30 to 85 relative humidity no condensation Storage...

Page 28: ...exit 3 Time Date setting Press the Menu button twice to enter this function Use the Menu button to select the year month date and time Press Up or Down to increase or decrease the values After complet...

Page 29: ...of day can influence your blood pressure Thus it is best to try and measure your blood pressure at the same time each day to get an accurate indication of any changes in blood pressure Blood pressure...

Page 30: ...ted blood pressure for an extended period of time may short your life expectancy A person s blood pressure is constantly changing Blood pressure can fluctuate considerably through the course of a sing...

Page 31: ...ent guidance for home healthcare environment Electrostatic discharge ESD IEC 61000 4 2 Contact 8 kV Air 2 kV 4 kV 8 kV 15 kV Contact 8 kV Air 2 kV 4 kV 8 kV 15 kV Floors should be wood concrete or cer...

Page 32: ...UT 250 300 cycle Voltage dips Not applicable Not applicable Not applicable Voltage interruptions Not applicable Mains power quality should be that of a typical home healthcare environment If the user...

Page 33: ...Hz or 60 Hz 30 A m 50 Hz 60 Hz The iBP 130 iBP 131 iBP 132 iBP 133 iBP 143 iBP 1XX XX 0 9 power frequency magnetic fields should be at levels characteristic of a typical location in a typical home he...

Page 34: ...Hz c Not applicable Not applicable 10 V m 80 MHz 2 7 GHz 80 AM at 1 kHz Portable and mobile RF communications equipment should be used no closer to any part of the iBP 130 iBP 131 iBP 132 iBP 133 iBP...

Page 35: ...y To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the iBP 130 iBP 131...

Page 36: ...imum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d...

Page 37: ...0 2 0 3 9 9 745 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 28 870 930 1 720 1 700 1 990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 Pulse mo...

Page 38: ...s and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that int...

Page 39: ...t Blood Pressure Monitor Model iBP 130 Technical Support Jian Bang Lee Address 2F No108 2 Min Chuan Road Hsin Tien Dist New Taipei City 231 Taiwan Telephone 886 2 2218 0150 Fax 886 2 2218 1552 e mail...

Page 40: ...39 Appendix III NCC Warning Statement NCC...