COMMISSIONING
Commissioning must take place in clean and well-lit areas. For the machine parts, refer to page
4 “General view” of this manual.
1 - After removing the packaging, make sure the machine is not damaged. Should you have any
doubt, do not use the machine and call your supplier’s technical support service.
The packaging materials (cardboard, wood, etc.) must be put away in special containers and
kept out of the reach of children as they are a potential source of hazard.
2 - Put the cleaner on a properly arranged place, in any case on an even surface, locking up the
castors using the brake (Fig. 2).
The work station must be equipped with:
- a mains outlet of 400V/16A 3+PH three-phase or 230V/16A single-phase 2PH+T according to
the models (see technical features on the rating plate - see section “Marking and
identification”)
- a clean water inlet 1/2”, pressure 0.3 Mpa, with a stop valve
- a connection to the drainage system for the treatment of the waste water.
Arrange for a good exhaust
system to evacuate gases and for
proper ventilation in closed rooms.
3 - Connect the machine water
inlet to the mains water; this
connection must be made with a
suitable hose, which must be as
short as possible to avoid tripping.
4 - After unscrewing the cap (Fig.
15), fill the tank with automotive
diesel. It is necessary to use clean
fuel; filter it if necessary.
5 - Connect the spray gun to the
high-pressure hose (Fig. 11) using a 17mm-spanner. Connect the latter to the fitting (Fig. 3).
6 - Connect the mains water hose to the quick coupling (Fig. 4) fixing it with a hose clamp. The
mains water hose must be perfectly clean inside; use a filter upstream if necessary.
7 -
CAUTION!
- Before wiring, turn the main switch (Fig. A) to 0/OFF and
make sure the rating plate data (Fig. 8) correspond to those of the mains
power supply. Wiring must be carried out by qualified personnel in
compliance with current national and local regulations.
8 -
CAUTION!
- Verify that the cross-section of the system cables, their
condition and their current carrying capacity are suitable for the power
absorbed by the machine, indicated on the rating plate. Protect the supply
line by using thermomagnetic releases coordinated with the machine
protection device. The data can be seen on the device itself.
Page 7
Summary of Contents for HYW10200
Page 1: ...ELECTRIC HOT WATER PRESSURE WASHER Models HYW11120 HYW10200 HYW13170 3 User Manual ...
Page 17: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 17 ...
Page 18: ...MX STANDARD THREE PHASE WIRING DIAGRAM Page 18 ...
Page 19: ...MC STANDARD THREE PHASE WIRING DIAGRAM Page 19 ...
Page 20: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 20 ...