PROBLEM
REASON
REMEDY
PUMP NORMALLY RUNS BUT
DOESN'T REACH THE REQUIRED
PRESSURE
Pump sucks air in
Operate the pump with spray gun open
Inlet/outlet valves worn or dirty
Clean or replace
Nozzle unsuitable or worn
Check and/or replace
Seals worn
Check and/or replace
Suction filter clogged
Clean or replace
Pin of control valve
Clean or replace
FLUCTUATING PRESSURE
Inlet/outlet valves worn, dirty or
clogged
Check/clean or replace
Air intake
Check that hoses and fittings are air tight
Seals worn
Check and/or replace
PRESSURE DROP
Nozzle worn
Replace nozzle
Inlet/outlet valves dirty
Check/clean or replace
Pin of control valve worn or clogged
Check and/or replace
Seals worn
Check and/or replace
NOISE
Air intake
Check that hose and fittings are air-tight
Inlet/outlet valves dirty, worn or
clogged
Check, clean and/or replace
Bearings worn
Check and/or replace
WATER IN OIL
Water-oil seal rings worn
Check and/or replace
WATER DRIPPING FROM PUMP
HEAD
Seals worn
Replace
O-ring worn
Replace
OIL LEAKS
Oil seal ring worn
Replace
THE MOTOR DOESN'T START
Not correctly plugged in
Check cable plug and switch
No power supply
Check cable plug and switch
THE MOTOR HUMS BUT DOESN'T
START
The mains voltage is insufficient,
lower than the minimum required
Check that the mains power supply
is adequate
The pump is stuck or frozen
Check by manually turning the motor
(see MAINTENANCE)
Incorrect extension cable
Replace extension cable
THE MOTOR SUDDENLY STOPS
Tripped thermal overload due to
overheating
Check that the mains voltage matches the
specifications. Switch off the motor and let
it cool for a few minutes
THE BURNER DOESN'T START
Lack of diesel
Check the diesel level and/or the float
Electrodes worn
Adjust (see MAINTENANCE)
Electrodes damaged
Replace
Diesel filter clogged
Replace
Diesel nozzle clogged
Clean the burner nozzle
Fuse of the burner and transformer
motor blown
Replace
The operations marked with the black square must be done only by qualified personnel
Page 15
Summary of Contents for HYW10200
Page 1: ...ELECTRIC HOT WATER PRESSURE WASHER Models HYW11120 HYW10200 HYW13170 3 User Manual ...
Page 17: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 17 ...
Page 18: ...MX STANDARD THREE PHASE WIRING DIAGRAM Page 18 ...
Page 19: ...MC STANDARD THREE PHASE WIRING DIAGRAM Page 19 ...
Page 20: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 20 ...