background image

7)

Regularly check the state of wear of the electrodes; electrode tips should be 3 mm apart.

8)

Replace the high-pressure water hose after every 2 years of activity.

The new hose must be clearly marked, i.e. with the maximum allowed pressure and the

manufacturer’s name or a suitable symbol. Before use, check the pressure values of the new 

hose as they must correspond to those of the cleaner. 

9)

Should the water filter get dirty or clogged, the water quantity is reduced, thus damaging the

pump. A slightly damaged filter doesn't work properly, thus causing damage to the pump, and

may let foreign matter in. Regularly (at least each 500 working hours) take the filter away and

clean it to remove dirt. In case of doubt replace the filter to avoid foreign matter coming into the

pump.

10)

The clogging of the nozzle, caused by either limescale or anything else, increases the pump

pressure, and damages it. It is necessary to regularly clean the nozzle.

11)

Regularly check the diesel filter and replace it if it is too dirty or damaged.

12)

Should the power cable get damaged, replace it by a special cable H07RNF, according to

the wiring. The replacement must be done by a specialized electrician.

CLOGGED NOZZLE - BY-PASS VALVE

 

IMPORTANT! 

Should the nozzle get clogged, the cleaner is equipped with a by-pass valve to 

automatically control the excess of pressure. 

The by-pass valve immediately reduces the pressure, to protect the mechanical parts of the 

pump and the motor. 

IN CASE THE BY-PASS VALVE IS TAMPERED WITH, THE MOTOR AND THE PUMP COULD 

BE PERMANENTLY DAMAGED! 

THE BY-PASS VALVE CAN BE REGULATED, CLEANED, REPAIRED OR REPLACED ONLY 

BY THE TECHNICAL SUPPORT SERVICE. 

Page 14

Summary of Contents for HYW10200

Page 1: ...ELECTRIC HOT WATER PRESSURE WASHER Models HYW11120 HYW10200 HYW13170 3 User Manual ...

Page 2: ...roubleshooting page 15 Disposal of the machine page 16 Ecological information page 16 Declaration of conformity page 16 Wiring diagram page 17 WARNINGS Carefully read the warnings given in these instructions since they provide important details concerning the safety use and maintenance Get acquainted with the appliance to be able to quickly switch it off and eliminate the pressure Make sure you re...

Page 3: ...hot water high pressure cleaner composed of a metal chassis with castors and a handle for moving generator for the production of hot water diesel burner diesel tank steam exhaust vent motor pump for inlet of pressurized water mains plug in power supply power cable and switchboard cover and washing spray gun or other accessories ENVISAGED CONDITIONS OF USE Use The cleaner has been developed and man...

Page 4: ...hose not supplied 8 Rating plate 9 Switchboard 10 Automatic gun 11 High pressure hose spray gun connection 12 Lance handgrip 13 Steam exhaust vent 14 Cover 15 Diesel tank Switchboard A Main switch B Thermostat control C Detergent regulation D Pressure gauge E Power supplywarning light F Burner warning light G Fuel warning light H Water warning light I Anti scaling warning light Page 4 ...

Page 5: ...G FEATURES THREE PHASE MODELS supply from three phase network with protection conductor without neutral conductor 400V 10 50Hz SINGLE PHASE MODELS supply from single phase network with protection conductor 230V 50Hz 10 continuous duty maximum ambient temperature 40 C minimum ambient temperature 5 C maximum humidity 80 sound pressure level 98 dB A Meticulous compliance with the instructions provide...

Page 6: ...jury to the operator and damage the machine We shall now give some examples of incorrect use WRONG CONNECTION USE OF THE ACCESSORIES SUPPLIED WRONG SEQUENCE OF STEPS FOR COMMISSIONING FAILURE TO USE GENUINE SPARE PARTS USE OF FUEL DIFFERENT FROM DIESEL STARTING THE MACHINE WITH DIESEL TANK ON EMPTY MAINTENANCE WORK BY UNQUALIFIED PERSONNEL USES FOR WHICH THE MACHINE HAS NOT BEEN DESIGNED see impro...

Page 7: ...r ventilation in closed rooms 3 Connect the machine water inlet to the mains water this connection must be made with a suitable hose which must be as short as possible to avoid tripping 4 After unscrewing the cap Fig 15 fill the tank with automotive diesel It is necessary to use clean fuel filter it if necessary 5 Connect the spray gun to the high pressure hose Fig 11 using a 17mm spanner Connect ...

Page 8: ...chine USE At the beginning of each working shift Verify that the supply cable the plug and the water hose are in good condition If they are damaged do not plug the machine into the mains and contact an after sales service centre for the replacement Check that the machine does not have visible damage Verify the efficiency of the main switch Verify the fuel level inside the tank to avoid damage to t...

Page 9: ...s light is continuously on when the burner is operating normally The light flashes available with optional device only in the event of burner malfunction Fuel warning light available with optional device only Lights up when the diesel fuel level is low Stop the machine and fill the tank with automotive diesel fuel Fig 15 page 4 Water warning light available with optional device only Indicates insu...

Page 10: ...eaned stop spraying and wait 3 4 minutes start the hot jet of water To avoid chemical deposits building up we suggest cleaning the machine by sucking up clean water for a few seconds Always clean small areas at a time because if the detergent gets dry it could damage the painted surfaces 3 STOP When you have finished using the machine act as follows A Shut off the gun B Turn the knob Fig A to 1 bu...

Page 11: ...must switch it off When using the machine in dangerous areas eg fuel service pumps keep to the relevant safety regulations The machine equipped with Total Stop or Stop n Go device automatically stops if it is inactive for more than one minute thanks to a safety device in order to avoid damaging the seals To use it again it is enough to open the spray gun If your machine has not the Total Stop afte...

Page 12: ...NTENANCE Warning If the machine is out of order or malfunctions such as oil or water leak immediately switch it off using the main switch and inform the qualified personnel Switch off the machine and disconnect the water and power supply and do not carry out any repair Immediately contact qualified personnel The repairs must be carried out by an authorised technical support service always using ge...

Page 13: ...d chemical deposits building up we suggest intaking clean water 5 The cleaning of the boiler must be done each 200 working hours as follows disassemble the nozzle and the electrode holder flange burner head clean the nozzle filter using compressed air and check the position of the electrodes take away the boiler cover and clean the baffle remove the inside cover unscrew the locking nuts of the coi...

Page 14: ... to avoid foreign matter coming into the pump 10 The clogging of the nozzle caused by either limescale or anything else increases the pump pressure and damages it It is necessary to regularly clean the nozzle 11 Regularly check the diesel filter and replace it if it is too dirty or damaged 12 Should the power cable get damaged replace it by a special cable H07RNF according to the wiring The replac...

Page 15: ...ves dirty worn or clogged Check clean and orreplace Bearings worn Check and orreplace WATER IN OIL Water oil seal ringsworn Check and orreplace WATER DRIPPING FROM PUMP HEAD Seals worn Replace O ring worn Replace OIL LEAKS Oil seal ring worn Replace THE MOTOR DOESN TSTART Not correctlyplugged in Check cable plug and switch No powersupply Check cable plug and switch THE MOTOR HUMS BUT DOESN T START...

Page 16: ... fitted directly on the water tap Disposal of the machine s packaging extracted dust parts replaced the machine altogether and the various liquids must be done in an environmentally friendly manner without polluting earth air and water and in any case complying with the relevant regulations in force INSTRUCTIONS FOR SUITABLE WASTE TREATMENT Ferrous materials aluminium copper recyclable materials t...

Page 17: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 17 ...

Page 18: ...MX STANDARD THREE PHASE WIRING DIAGRAM Page 18 ...

Page 19: ...MC STANDARD THREE PHASE WIRING DIAGRAM Page 19 ...

Page 20: ...MX STANDARD SINGLE PHASE WIRING DIAGRAM Page 20 ...

Page 21: ... MUST recycle WEEE in accordance with your local authority or recycling centre Battery recycling certain products contain batteries which should not be disposed of in your domestic waste You MUST recycle batteries in accordance with your local authority or recycling centre Unwanted packaging materials should be sorted and taken to a recycling centre so it can be disposed of in a manner which is co...

Page 22: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerequipment co uk ...