background image

Figure 4-1 

Figure 4-2 

Operating Instructions 

 

1. Gently squeeze the opposite ends of the thermometer to pull off the probe cap. Do not use force in 

removing the cap. 

2. Press the “ON/MEM” button (located below the LCD display).  
3. The thermometer is ready for use after the ear icon stops flashing and 

two beeps are sounded. 

4. Gently pull the ear back to straighten the ear canal and snugly position 

the probe into the ear canal, aiming towards the membrane of the 
eardrum to obtain an accurate reading ( Fig.4-1)  

5. Measuring the ear temperature: Use the index finger to hold the “Scan” button (located other side of 

LCD display at the top) down until you hear a beep ( Fig. 4-2 ). 

6. Remove the thermometer from ear, the temperature reading will display 

on LCD screen. 

7.   To turn off thermometer, hold down “ON/MEM button until you see “OFF” on LCD display or device 

will automatically shut off after 1 minute to extend battery life.  

8.   Replace probe cap after use. 

 

Holding the thermometer too long may cause a higher ambient temperature reading of the probe. 

This could make the body temperature measurement lower than usual.

 

 

Switching between Fahrenheit and Celsius 

To change the LCD from °C to °F: When the unit is OFF, hold down the “Scan” button, then press 
and hold the “ON/MEN” button until the LCD shows ‘°F’, then release the “Scan” button. Use the 
same process to change the LCD display from °F to °C. 

 

Memory Function 

This ear thermometer can store up to 9 readings. The memory function allows you to make temperature 
comparisons for evaluation of temperature trends. 

 

Using Memory Function 

 

1.  If the reading of the thermometer is within the normal temperature range of 93.2

 o

F to 108.0

o

F (34

o

C to 

      42.2

 o

C), the last measurement data is saved into memory after the thermometer is turned off.  

     ** Press the “ON/MEN” button again to see the temperature stored. 
2. To recall memory, press the “ON/MEM” button. The LCD display will show the temperature reading  
     stored in Memory 1. 
3.  Press “ON/MEM” button again to see the temperature stored in Memory 2. Repeat this process to see  
     temperature measurements stored in all memory locations. 

Cleaning and Storage 

The Probe is the most delicate part of the thermometer. Use with care when cleaning the probe to avoid 
damage.  Gently clean the exterior and LCD display with a mild solution and do not submerge unit in 
water or any other liquids. Keep the unit dry and away from direct sunlight.  
After each use, please use the alcohol swab or the soft cotton moistened with the 70%

 

alcohol to clean 

the probe. 

Summary of Contents for HT801

Page 1: ...oid the risk of cross contamination please use the thermometer individually 5 Clean the thermometer before and after each use store in the case provided with the thermometer 6 The thermometer should only be used under the supervision of an adult Do not allow children to take their temperatures unattended Prohibit children from biting hitting or removing the battery cover dislodging and potentially...

Page 2: ...ge the LCD from C to F When the unit is OFF hold down the Scan button then press and hold the ON MEN button until the LCD shows F then release the Scan button Use the same process to change the LCD display from F to C Memory Function This ear thermometer can store up to 9 readings The memory function allows you to make temperature comparisons for evaluation of temperature trends Using Memory Funct...

Page 3: ...age Problem Solution Device stabilization in process Wait until stops flashing Battery is low and no more measurements are possible Replace the battery Measurement taken before device stabilization Wait until stops flashing The device showing a rapid ambient temperature change Allow the thermometer to rest in a room for at least 30 minutes at room temperature 50 o F 104 o F 10 o C and 40 o C The a...

Page 4: ...IENT RANGE 50 104 F 20 50 C STORAGE RANGE 4 122 F MEASURE TIME About 1 sec TIME BETWEEN MEASUREMENT 5 sec DISPLAY MODE ORAL SCALE SELECTION C F DISPLAY TYPE LCD MEMORY 9 set DISPOSABLE PROBE COVER Without Probe Cover ACTIVATION SCAN BUTTON DESIGN HANDHELD SENSOR TYPE Thermopile BATTERY TYPE CR2032 1pc ...

Page 5: ...exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the above exclusions or limitations may not apply to you This warranty gives your specific legal rights and you may also have other rights which vary from state to state Should your product become defective during this warranty period please return the product in the original cart...

Page 6: ...e termómetro ha sido diseñado para su uso práctico y no para reemplazar su visita al médico 15 Para evitar el riesgo de contagio y contaminación por favor use el termómetro individualmente 16 Limpie el termómetro antes y después de cada uso y guárdelo en el estuche que trae consigo 17 El termómetro debe usarse únicamente bajo la supervisión de un adulto No permita que los niños tomen su temperatur...

Page 7: ...agar el termómetro mantenga apretado el botón que dice ON MEM hasta que vea OFF en el panel LCD De otro modo el dispositivo se apagará automáticamente después un minuto para que las pilas duren más 16 Vuelva a poner la tapa de de la sonda una vez que termina la medición Mantener agarrado el termómetro por mucho tiempo puede hacer que la punta de la sonda lea una temperatura ambiente más alta Esto ...

Page 8: ... sostenido el dispositivo y saque la pila con un destornillador pequeño 7 Ponga la nueva pila debajo del gancho de metal del lado izquierdo y presione el lado derecho de la pila hacia abajo hasta que escuche un click Ubique el polo positivo hacia arriba y el negativo hacia abajo 8 Vuelva a poner la tapa El termómetro puede dañarse si cambia la pila cuando la unidad está encendida Por eso debe apag...

Page 9: ...al de inicio Ponga una pila nueva Datos técnicos Especificación HT801 34 0 42 2 C RANGO DE MEDICION 93 2 108 0 F 10 40 C RANGO DE TEMPERATURA AMBIENTE 50 104 F 20 50 C TEMPERATURA DE ALMACENAMIENTO 4 122 F TIEMPO DE MEDICION 1 segundo TIEMPO ENTRE MEDICIONES 5 segundos MODO DE PRESENTACION ORAL SELECCION DE ESCALA DE MEDICION C F TIPO DE PANEL LCD MEMORIA 9 grupos TAPA DE SONDA DESCARTABLE Sin cob...

Page 10: ... sobre la cantidad de tiempo que dura una garantía Por eso las exclusiones o limitaciones establecidas más arriba pueden no aplicarse a su caso Esta garantía le da derechos legales específicos y usted puede también tener otros derechos que varían de un Estado a otro Si su producto muestra problemas de funcionamiento durante el período cubierto por esta garantía por favor devuélvalo en su caja orig...

Reviews: