36
The Settings Menu provides options typically used upon initial setup or at the start of a new project. Follow
instructions on the screen to select and change the desired settings. All Settings Menu items except Bluetooth and
App Mode are available to users at access level L3 (Full User) and above.
The tool can display torque in foot-
pounds (ft-lbs), Newton-meters (N-m),
kilogram force meters (kgf-m) or as
a percentage of the maximum rated
torque of the tool (%). The currently
selected units are highlighted.
Selecting any other units will display
all torque values with those selected
units.
The Clock option allows the user to
set time and date. First set the time
by using the left and right buttons to
increase or decrease the highlighted
value. Press the center button to select
and move to the next position. Use the
same method to enter the date. Once
complete the user can either Accept,
Retry or Cancel entry.
UNITS
CLOCK
Set time and date.
Set limits on
Torque operations.
Enable/disable
the work light.
Display torque in ft-lbs,
N-m, kgf-m or %
of maximum torque.
Used to sync tool
with HYTORC
bolting software.
Configure Bluetooth
Settings.
Set limits on
Angle operations.
Turn notification
beeper on or off.
Turn the menu icons
on or off.
Set button
response time.
Adjust time between
Torque, Angle
and Release.
Flip Screen
(for when the tool
is inverted).
Enable/disable
5 minutes
automatic shutdown.
(CONT ’ D.)
10. SET TINGS