LITHIUM SERIES® II ELECTRIC TORQUE TOOL USER INTERFACE GUIDE
21
•
Pull and Hold the Trigger
– If tool is set to RH or LH Fastener, a message
instructs the user to press any button to start, in order to ensure that hands
are kept clear of the reaction arm.
•
Continue Holding -
The tool will apply torque and rotate the nut until the
tool motor stops at the specified Torque value. During Torque application the
Torque function is highlighted yellow. Continue holding trigger if a Release
angle has been set. Observe the socket/nut during operation to see if any
motion occurs.
•
Hold for Release -
Continue holding the trigger if a non-zero Release has
been specified and the tool will restart (after specified time delay) and then
stop again after completing the Release angle.
NOTE:
If Torque has been applied without a Release angle and the tool locks
onto the nut, loosen the nut, set a Release angle and try tightening again.
•
Monitor Screen and Status LED
- The status light is amber during operation.
If the operation is successful, the status light will illuminate green; if
unsuccessful the status light will turn red. The final screen displayed will have
a green check mark. If unsuccessful the final screen will have a red X.
•
Release Trigger
- Release the trigger after the tool has completed all
specified operations, the tool stalls for the last time and the Beeper sounds
(if activated); then remove the tool socket/drive from the nut.
TIGHTENING WITH TORQUE CHECK
(CONT ’ D.)
(CONT ’ D.)