![Hytorc LITHIUM II Series Basic Operation Manual Download Page 29](http://html1.mh-extra.com/html/hytorc/lithium-ii-series/lithium-ii-series_basic-operation-manual_2194805029.webp)
LITHIUM SERIES® II
Electric Torque Tool Operations Manual
24
NOTE: The HYTORC Nut inner sleeve is tightened in the counter clockwise direction (left hand threads).
•
Power on the tool, select the desired torque using the up and down arrow buttons and set the fastener type to
HYTORC Nut
•
Position the tool over the nut
•
Pull the trigger to apply torque until the tool stalls at the specified torque
•
If a RELEASE ANGLE has been specified continue holding the trigger and the tool will restart and then stall again
after completing the RELEASE angle. Then the tool can be released from the nut.
•
Release the trigger after the tool has completed all specified operations
•
The status light will turn amber during operation. If the operation is successful, the status light will turn green, if
unsuccessful the status light will turn red.
•
If the BEEPER is enabled the tool will provide an audible beep upon completion of the operations
•
Remove the tool driver from the nut
•
Should torque be applied without a release angle the tool may lock onto the nut. If this happens set the tool to
loosen to free the tool and repeat the tighten operation.
TIGHTENING THE HYTORC NUT
(CONT ’ D.)