![Hytorc LITHIUM II Series Basic Operation Manual Download Page 12](http://html1.mh-extra.com/html/hytorc/lithium-ii-series/lithium-ii-series_basic-operation-manual_2194805012.webp)
7
CHARGE THE BATTERY
•
The LITHIUM SERIES® II Tool is supplied with the HYTORC Battery Charger (Model: A000791) and two long-life
HYTORC 36-volt batteries (Model: P002036-1)
•
Before charging a battery verify the local voltage supply to ensure capability with the charger; this will typically be
110 Volts or 220 Volts AC.
•
Only operate the battery charger between 32°F (0°C) to 104º F (40º C) and with 10% to 90% ambient relative
humidity (no condensate)
•
Connect the charging cradle to the power supply
•
Connect the power cord to a grounded outlet
•
If necessary connect the plug adapters to the local power outlet
•
Insert the battery by sliding it into the charger and locking into place
•
The 36-volt battery is fully charged in approximately 90 minutes
CHARGING/FAULT INDICATOR
•
POWER INDICATOR green when charger is plugged into AC outlet
•
CHARGING/FAULT INDICATOR is flashing green while battery is charging
•
CHARGING/FAULT INDICATOR solid green when battery is fully charged
•
CHARGING/FAULT INDICATOR is flashing red for battery fault not charging
BATTERY STORAGE
•
Only store the battery and charger in the following environmental conditions:
•
-4°F (-20°C) to 122°F (50°C) 5% to 95% ambient relative humidity
Charging Cable
Battery Pack
Charging Cradle
Power Indicator
Charging/Fault Indicator
Legend
Power Supply
Power Supply Cord
4. CHARGE , TEST AND INSTALL BATTERY