A.
INSERT SCREWDRIVER HERE
1. EMERGENCY DISCONNECT SWITCH
2. SWITCH ADAPTER
3. LOCK
4. NUT
5. EMERGENCY DISCONNECT BUTTON
6. BUSHING
7. UPPER REAR COVER
8. HOLE
Figure 12. Emergency Disconnect Switch
Replacement
3.
Install switch adapter and lock onto emergency
disconnect button assembly. Install switches,
by pushing switches onto switch adapter until
switches clicks into place. Connect main wire
harness to emergency disconnect switch. See
Figure 8.
4.
Connect the Direction Control Switch if lift
truck is equipped with this function. See Fig-
ure 8.
5.
Install and tighten five socket head capscrews
to secure upper rear cover to manual lever as-
sembly. See Figure 12.
6.
Install upper front cover. See section Upper
Front Cover for procedures.
Attachment Button (Fourth Function)
Remove
1.
Read and follow the WARNING and CAU-
TION section in the General section above.
2.
Remove upper front cover. See section Upper
Front Cover for procedures. Disconnect manual
control valve wire harness from direction con-
trol switch. See Figure 8.
3.
Remove two outer capscrews and attachment
switch handle from manual aux 2 lever. See
Figure 9.
4.
Remove one inner capscrew and palm side grip
handle from manual aux 2 lever. See Figure 9.
5.
Remove push-button cable from cable track.
See Figure 9 and Figure 13.
Install
1.
Route push-button cable through cable track on
manual aux 2 lever. See Figure 9 and Fig-
ure 13.
2.
Install palm side handle and one inner cap-
screw on manual aux 2 lever. See Figure 9.
1. ATTACHMENT BUTTON
2. THIRD MANUAL CONTROL LEVER
Figure 13. Attachment Button
2200 SRM 1524
Electronic and Manual Hydraulic Controls
11