1. SCREW
2. DIRECTION CONTROL SWITCH RETAINER
3. DIRECTION CONTROL SWITCH CUP
4. DIRECTION CONTROL SWITCH CABLE
Figure 10. Direction Control Switch
Emergency Disconnect Switch
Remove
1.
Read and follow the WARNING and CAU-
TION section in the General section above.
2.
Remove upper front cover. See section Upper
Front Cover above for procedures.
3.
Remove five socket head capscrews from upper
rear cover. See Figure 11. Pull cover forward to
generate enough space to disconnect the emer-
gency disconnect switch wires. See Figure 8.
1. SOCKET HEAD SCREWS
2. UPPER REAR COVER
3. LEVER LINKAGE
4. MANUAL HYDRAULICS WIRE HARNESS
Figure 11. Upper Rear Cover Removal
4.
Disconnect the Direction Control Switch if lift
truck is equipped with this feature. See Fig-
ure 8.
5.
Insert screwdriver or other flat tipped tool into
slot on side of switch. Pull tool up to remove the
emergency disconnect switch, switch adapter,
and lock from upper rear cover. See Figure 12.
6.
Remove nut from upper rear cover. Remove
emergency disconnect button and bushing from
hole in upper rear cover. See Figure 12.
Install
1.
Insert the emergency disconnect button and
bushing into hole in upper rear cover. See Fig-
ure 12. Place nut on button and turn it clock-
wise to secure emergency disconnect button and
bushing
in
hole.
Tighten
nut
to
2 N•m (18 lbf in).
2.
Connect wires to emergency disconnect switch.
Tighten screws to 0.8 N•m (8.55 lbf in) typical;
1.2 N•m (10.7 lbf in) maximum.
Electronic and Manual Hydraulic Controls
2200 SRM 1524
10