1. EMERGENCY DISCONNECT SWITCH CON-
NECTOR
2. MANUAL CONTROL VALVE WIRE HARNESS
3. DIRECTION CONTROL SWITCH CONNECTOR
Figure 8. Manual Control Levers Assembly
Electrical Components
3.
Remove two outer capscrews and lift/lower with
Direction Control Switch handle from manual
lift/lower lever. See Figure 9.
4.
Remove one inner capscrew and palm side grip
handle from manual lift lever. See Figure 9.
5.
Remove Direction Control Switch cable from ca-
ble track. See Figure 9.
6.
Remove two screws, Direction Control Switch
retainer, Direction Control Switch cup, and Di-
rection Control Switch from lift/lower with Di-
rection Control Switch handle. See Figure 10.
Install
1.
Install DCS into DCS cup. See Figure 10.
2.
Install DCS cup and DCS into lift/lower Direc-
tion Control Switch handle. See Figure 10.
3.
Install DCS retainer onto back side of DCS cup,
inside lift/lower with DCS handle. See Fig-
ure 10.
4.
Install two screws through retainer and DCS
cup into DCS. See Figure 10.
5.
Route DCS cable through cable track on man-
ual lift/lower lever. See Figure 9.
6.
Install palm side handle and one capscrew on
manual lift/lower lever. See Figure 9.
7.
Install lift/lower with DCS handle and two
outer capscrews on manual lift/lower lever.
Tighten outer capscrews 1.35 to 1.65 N•m (11.9
to 14.6 lbf in). See Figure 9.
8.
Install upper front cover. See section Upper
Front Cover for procedures.
Electronic and Manual Hydraulic Controls
2200 SRM 1524
8