Table 22. Smart DC Controller - Troubleshooting

Display 

Condition

Description 

Alert, Error or 

Fault

Possible Causes

Solutions

ALERT 6 LIM 

NOT RELEASED

The limit did not 

release when 

the operator was 

commanded to 

move.

 

z

Broken drive belt.

 

z

Hardware holding the arm.

 

z

Tighten taper clamp 

(SwingSmart DC)

 

z

Check/replace drive 

belt.

 

z

Remove debris from 

limit area

 

z

Check limit switches 

and replace as 

required

 

z

Check limit plate

 

z

Release any holds 

on the arm.

 

z

Relearn Limits. 

(StrongArmPark DC 

and WedgeSmart 

DC)

ALERT 7 

FREQ SHIFT 

FAULT

H Y - 5 B   h a s 

d e t e c t e d   a 

frequency change 

outside  normal 

range.

Likely  causes  are  poor  integrity  of 

loops or metallic objects within range. 

This message will also indicate which 

detector  alert  applies  to:  Exit  Loop 

(ELD), Inside Obstruction Loop (IOLD), 

Outside Obstruction Loop (OOLD), or 

Center Loop (CLD) - (User Relay 22). 

Loop lead in wires and 

roadway  should  be 

checked  for  problems 

or replaced.

ALERT 8 

LOOP SHORTED

H Y - 5 B   h a s 

d e t e c t e d   a 

loopshorted  to 

ground.

Caused  by  inadequate  insulation  of 

loop wires.

Loop lead in wires and 

roadway  should  be 

checked  for  problems 

or replaced.

ALERT 9 

LOOP OPEN

H Y - 5 B   h a s 

detected  a  lack 

of  continuity  in 

loop wire.

Caused  by  broken  loop  wire  or  wire 

has come unplugged from detector.

Loop and lead in wires 

should be checked for 

problems or replaced.

ALERT 10 

12C BUS ERROR

Smart DC 

Controller has 

detected a 

communication 

error with a 

HY-5B vehicle 

detector.

Caused  by  removal  of  HY-5B  or  lack 

of  integrity  of  socket  connection. 

This message will also indicate which 

detector  alert  applies  to:  Exit  Loop 

(ELD), Inside Obstruction Loop (IOLD), 

Outside Obstruction Loop (OOLD), or 

Center Loop (CLD) - (User Relay 22).

Remove and re-install 

the HY-5B and press 

RESET. Replace HY-5B, 

if necessary.

REFERENCE

127 

| www.hysecurity.com 

SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL 

MX3640-01 REV. D  ©2018

Summary of Contents for SwingSmart DC 20

Page 1: ...DC20 DCS20 Programming and Operations Manual Pad mounted electromechanical swing gate operator with Smart DC Controller Industrial Commercial Crash Parking Residential 800 321 9947 253 867 3700 www h...

Page 2: ...2 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...

Page 3: ...RAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018 SWINGSMART DC 20 GATE OPERATOR SWINGMART DCS 20 GATE OPERATOR PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REVISION D HYSECURITY CORPORATE HEADQUARTER...

Page 4: ...115VAC Power 41 Wiring 208 230VAC Power 42 Connecting DC Power 43 Using a Solar Powered Operator 43 Design Requirements Considerations 44 Connecting the SwingSmart DCS 20 to Solar Power Panels 45 Con...

Page 5: ...ntrols 103 Software Maintenance 103 Electrical Controls 103 Clock Battery Replacement 103 Fuse Replacement 104 Mechanical Maintenance 104 Drive Belt Tension and Alignment 105 DC Battery Replacement 10...

Page 6: ...juststhegatespeedtosynchronize the left and right gates so that they reach the open and close positions at the same time Independent leaf delay adjustment for bi parting gates is selectable in second...

Page 7: ...Cover Cover Pulley Motor Motor Brush Kit Battery Kit 50AH Battery Kit 8AH Handle Clamp Clamp Assembly Limit Plate Blocks Limit Switch Kit Bracket Limit Swith Knob Top Cover Detector Vehicle MX4535 SE...

Page 8: ...Complete Initial Setup Menu programming Review the connections on the Smart DC Controller Install Primary Secondary operator connections if the site is a bi parting gate system Attach accessory devic...

Page 9: ...SAFETY SYMBOLS DANGER Indicates a hazardous situation which if not avoided WILL result in DEATH or SERIOUS INJURY WARNING Indicates a hazardous situation which if not avoided COULD result in DEATH or...

Page 10: ...death Start gate operator only when the gate s travel path is clear 2 Never let children operate or play with gate controls Keep all remote controls especially radio transmitters away from children D...

Page 11: ...maged gate Make sure all exposed pinch points rollers and wheels are guarded Reduce entrapment risk throughout entire travel path make sure gate is installed in a location so enough clearance is suppl...

Page 12: ...tes are for vehicular use only provide and maintain walkways and signs to direct pedestrians to a separate walk through entrance An automatic gate can start at any time without warning always keep peo...

Page 13: ...n and safety decals when they become dif cult read Manufacturer does not assume responsibility for any accident due to equipment modi cations Unauthorized equipment modi cation will void all warrantie...

Page 14: ...d state of the art Absorbed Glass Mat AGM batteries and highly recommends replacing used batteries with new AGM type batteries To reduce risk of re or injury to persons Observe polarity between batter...

Page 15: ...al and plastic recycling center promotes energy cost savings EXTERNAL ENTRAPMENT PROTECTION SENSORS Most HySecurity gate operators are equipped with a Type A Inherent Entrapment Sensor IES UL 325 Safe...

Page 16: ...al is not impeded by building structures or other obstructions All sensors must be installed so that they function as intended for end use conditions UL 325 LISTING Edge sensors and photo electric eye...

Page 17: ...ch as a multi family housing units ve or more single family units hotels garages retail stores or other buildings servicing general public Class III Class III Intended for use in an industrial locatio...

Page 18: ...ng B1 install non contact sensors photoelectric sensor or equivalent according to instructions To comply using B2 install contact sensors edge sensor device or equivalent according to instructions To...

Page 19: ...perator s motor runs or is always powered when the operator is connected to AC power Table 1 Sensors Tested for Use with HySecurity Operators Mfg Part Mfg Details Hysecurity Part Photo Eyes Retrore ec...

Page 20: ...pear CAUTION EMX IRB MON Photo Eye Transmitter CAUTION Set DIP Switches 1 OFF 2 OFF 3 OFF 4 ON NOTE DIP switches mustbe set as shown otherwise the photo eye will not operate correctly Jumper POWER INP...

Page 21: ...nd Leading End PUBLIC SECURE 5 4 3 2 1 6 Swing Gate Potential Zones for Entrapment Protection 1 Leading Edge 2 Bottom Edge 3 Entry Exit 4 Posts 5 Post Pivot Pinch Points 6 Arm Movement SECURE PUBLIC I...

Page 22: ...t maximum wind speed in areas around the United States search for US government wind speed maps on the internet If you don t know how to calculate for wind load ask a mechanical engineer or site archi...

Page 23: ...allows a gate to be pushed manually when the taper clamp is loosened It is recommended that you turn off DC power which disengages the motor allowing you to easily move the gate When you turn DC power...

Page 24: ...SAFETY INFORMATION 24 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...

Page 25: ...pproximately 10 to 15 seconds Variable speed open close separately Gate weight 1 300lbs 12ft leaf 590kg 4m leaf 1 300lbs 12ft leaf 590kg 4m leaf Secure Side Public Side WARNING Pedestrian gate Make su...

Page 26: ...e design also provides a 9 6 inch 24 4cm height between the control box and chassis base for pulling and placement of wires CAUTION Be sure to restrict conduit to the 6 x 7 inch 15 2 x 17 7cm cutout i...

Page 27: ...ng conduit is permissible but not recommended because it can impair the strength of the chassis and void the Limited Warranty UNPACKING THE OPERATOR Prepare the gate operator for installation See Figu...

Page 28: ...Y dimension at 30 35 or 40 76 89 or 102cm 3 Set the operator base on the concrete pad and use it as a template Position the operator base so the center mark on the pad aligns with the small hole in th...

Page 29: ...Bracket CAUTION Consider positioning the operator so existing conduit exits through the cutout in the SwingSmart base plate Cutting small holes in the base plate for pre existing conduit is permissibl...

Page 30: ...he taper clamp assembly using the fasteners removed in step 2 4 Pull the taper handle to lengthen it Adjust the handle so the ball detent fits into its cutout and secures the handle length Turn the ha...

Page 31: ...nches 121cm A B INSTALLATION Table 3 Gate Linkage Arms Installation Dimensions Short Gate Installation For gates up to 10 feet 3 meters X Y Xg A B 10 5 27cm 14 36cm 23 5 60cm 15 5 39cm 21 5 55cm 18 46...

Page 32: ...71cm 40 5 103cm 120 32 81cm 20 51cm 41 104cm 31 5 80cm 44 112cm 130 38 97cm 18 46cm 44 112cm 36 91cm 47 5 121cm NOTE Maximum A 38 97cm NOTE Maximum B 47 5 121cm NOTICE The linkage tubes used for the...

Page 33: ...If the pivot bolt is not vertical binding of the arm assembly may occur during operation Set screw The set screw serves as a physical stop when the gate is closed Middle set screw hole allows a slight...

Page 34: ...djust the limit cams use a Phillips head screwdriver and loosen the fastener that secures each limit cam to the limit plate 3 Manually open and close the gate Move the limit cams so they trip the appr...

Page 35: ...g the elbow with a slight offset at the full close position Use the supplied set screw in middle position to prevent the arm from locking The intent of the offset is that upon gate strike the elbow wi...

Page 36: ...es not recommend it The preferred method is an installation where the gate arm remains horizontal throughout gate travel z z A gate must be neutrally balanced To comply with ASTM F2200 General Require...

Page 37: ...ting the taper clamp until after the operator has been configured to run Refer to Configuring the Setup Menu on page 55 1 To loosen and release the taper clamp extend the taper handle and turn the han...

Page 38: ...nds the motor turns off and the buzzer continues for another 30 seconds ALERT 1 FORCED OPEN appears on the display An OPEN or CLOSE command clears the alert and resets the display z z Fully straighten...

Page 39: ...E Properly grounding the gate operator is critical to gate operator performance and the life of its electrical components Use sufficient wire size during installation If you do not ground the operator...

Page 40: ...ed to the 230V position or damage to the operator will occur and void the Limited Warranty Figure 18 Wiring AC Power Voltage selector switch is factory set to 115V If power input is 208 230V move the...

Page 41: ...t the wire size be increased or the distance of the run be decreased To connect to 115VAC power take the following steps 1 Make sure the AC power is turned off at its source and the DC and AC power sw...

Page 42: ...tection cover and secure it NOTICE Table 6 assumes a dedicated circuit Additional loads require that the wire size be increased or the distance of the run be decreased 4 Access the input power wires b...

Page 43: ...harger which allows a 24V solar panel or two 12V panels a direct connection to the SwingSmart operator with no additional electronic devices required To plan a solar powered site read through this ent...

Page 44: ...teries z z Solar hours at the site Solar hours relate to the amount of energy delivered by the sun and absorbed by the solar panels It is NOT the same as the number of daylight hours available at the...

Page 45: ...crimp bond the equipment ground wire to the green ground wire in the junction box 6 Slide the plastic cover off the control box and attach the red spade connector to the battery terminal on the upper...

Page 46: ...Solid state 24VDC 24VDC 12VDC 12VDC Press button to light active inputs COM B A DUAL GATE COM OPEN 24V RADIO OPTIONS S1 COM NO USER2 DC Amp Draw on Power Supplies Two power supplies are available 24V...

Page 47: ...which usually draw at minimum 0 009A Understanding Gate Activity based on Solar Zones Use the solar maps to determine the number of solar hours per day that can be reasonably expected in a particular...

Page 48: ...with the gate travel occurring throughout the night determines the battery capacity required The number of amps that the peripherals draw coupled with the gate travel during the day determines the so...

Page 49: ...tteries contain sulfuric acid Acid in your eyes on your skin or on your clothing can cause injury and severe burns If batteries are dropped or damaged dispose of them properly POWER z z Batteries are...

Page 50: ...fully rotate the support tray to access the battery wires Lift the 8Ah batteries from the support tray Disconnect the black and blue wires and set the 8Ah batteries aside 6 Return the support tray to...

Page 51: ...1 Start at a gate status display 2 To access the User Menu press the MENU button twice 3 Access the Installer Menu by simultaneously pressing the OPEN and RESET buttons 4 Use NEXT to navigate to the...

Page 52: ...into the field A S T A R T User Guide is also available online CAUTION Smart DC Controller can be powered when either switch is turned on The operator is a DC powered unit and runs on its batteries If...

Page 53: ...the Setup Menu z z Error message indicates a problem exists with the operator which needs to be resolved before the operator can function properly Left Handing Right Handing NOTICE If AC power is los...

Page 54: ...he RESET button or cycling power Faults indicate a need for diagnosis and resolution Refer to Smart DC Controller Troubleshooting on page 123 Figure 30 Function of the Smart DC Controller Buttons in M...

Page 55: ...Menu Refer to Reinstating Factory Defaults on page 82 Figure 31 Configuring the Setup Menu SH 0 GATE HANDING OPEN CLOSE STOP MENU RESET PREV NEXT SELECT UC 0 USAGE CLASS OPEN CLOSE STOP MENU RESET PRE...

Page 56: ...ressing Open Close or Stop causes the gate to perform the command Pressing Reset clears alerts or faults and returns to Run Mode NOTE Press Reset at any Run mode status display to view the software ve...

Page 57: ...a dual gate setting whether operator is set to Primary or Secondary Setting is assigned in Installer Menu Operator Type OT OT 12 SwingSmart DC or DCS Indicates and identifies the operator Set Handing...

Page 58: ...e not counted Displays number of cycles gate operator has incurred Similar to an odometer it resets to zero after 999 999 cycles Close Timer CT The first menu item in the User Menu See User Menu on pa...

Page 59: ...st be in Run Mode The motor cannot be engaged and the gate cannot be moving ADJUSTING THE CLOSE TIMER The close timer assigns how many seconds will pass before the operator initiates automatic closure...

Page 60: ...s on the date and time display press SELECT 8 To exit the User Menu press the MENU button A gate status appears in the display indicating you have returned to Run Mode NOTICE A date or time field must...

Page 61: ...open or close command is ignored and LCD appears blank System remains in this disabled state until reset or battery recovers to 24V AP 2 AC LOSS AUTO OPEN Operator automatically opens gate five second...

Page 62: ...E TIMER display appears 2 Press NEXT until the LCD CONTRAST display appears 3 Use the SELECT and NEXT buttons to navigate and change the number on the display 4 To exit the User Menu press the MENU bu...

Page 63: ...matic close timer and causes its menu to disappear You must set HC to 1 to comply with UL 325 Type D protection Refer to Table Notes COM CLOSE HO 0 OFF Hold to Open 0 off 1 on SimilartoHOLDTOCLOSE but...

Page 64: ...death FA 0 OFF Forced Open Alert 0 off 1 on Intended for highly secure facilities Set to 1 the operator sounds the 3 second warn before operate buzzer alarm and initiates a closure if the gate is for...

Page 65: ...te on page 60 N A LD 5 LCD Contrast 5 0 through 9 Under some extreme high or low temperature conditions it may be necessary to adjust LCD contrast Display is adjustable from 0 9 with a factory default...

Page 66: ...ce numbered menu selections Table Note 1 For gate operators using Type D entrapment protection an automatic closing device such as a timer loop sensor or similiar device shall not be employed Table No...

Page 67: ...e operator must be in Run Mode with a gate status showing on the display The motor cannot be engaged and the gate cannot be moving NOTICE The menu items Usage Class Gate Handing Gate Weight and Gate L...

Page 68: ...e operator model used at the site NOTE This menu item only appears if applicable when you set the OT operator type N A LL 0 OFF Learn Limit 0 Normal operation 1 Reset limits A setting of 1 places oper...

Page 69: ...e motor and the gate opening speed increases as you go up the number scale A setting of 1 slows the gate travel to approximately 15 seconds A setting of 10 speeds up gate travel to approximately 10 se...

Page 70: ...s communication after wiring twoormoregateoperatorsassequential gates This SG menu item only appears if the Dual Gate menu item DG is set to 0 solo operator NOTE After selecting SG settings consider a...

Page 71: ...ware See Note SS 0 OFF IES STOP ONLY 0 stop reverse for 2s 1 stop only In a Usage Class 4 environment operator can be set to stop gate and not reverse gate travel after an IES trip N A LC 0 0 0 SECS L...

Page 72: ...Sensor Common Sensor Input EO 0 STOP ONLY EYE OPEN LOGIC 0 Open eye stops only 1 2s reverse to close Default setting is non reversal if open photo eye is triggered while opening A setting of 1 causes...

Page 73: ...ires an NO output S e n s o r Common Sensor Input S1 0 Sensor 1 Type 0 disabled 1 NOT USED 2 EYE CLOSE 3 EDGE CLOSE 4 EYE OPEN 5 EDGE OPEN 6 EDGE BOTH 7 EYE BOTH UL 325 2018 sensor input setting for e...

Page 74: ...ction of the Center Loop Shadow Loop when triggered Setting 1 prevents opening and closing of the gate when the Center Loop is tripped if the gate is on either opened or closed limit switches Setting...

Page 75: ...an electronic relay with capacity for switching a DC load only The User 2 Relay is limited to 48 Volts DC and 4A maximum load Up to 45 optional relay functions exist See Figure 68 Setting the User Rel...

Page 76: ...o 99 Network drop address Set system address for network communication 0 no network communication 1 99 sets individual polling addresses Use addresses 1 4 when connecting to HyNet RS 485 ELD0 RUN MODE...

Page 77: ...Controller Display Connections CLD 0 RUN MODE CENTER LOOP SET 0 Run mode 1 Show frequency 2 Show call level 0 7 3 Set Frequency Controls HY 5A or HY 5B Center Loop Shadow detector If an HY 5B is used...

Page 78: ...taller Menu press the MENU button The gate status appears in the display indicating you have returned to Run Mode NOTICE Two options one for OPEN SPEED the other for CLOSE SPEED appear in the Installe...

Page 79: ...fault setting is 0 5 Use NEXT button to change number on display to 1 and then press SELECT 6 To exit Installer Menu press MENU button Gate status appears in display indicating you have returned to Ru...

Page 80: ...threshold Over time degrading gate hardware and other site issues such as road settling or debris on the gate rail V track can occur As the gate hardware ages and becomes stiffer the SwingSmart motor...

Page 81: ...ory default setting is 2 4 Use the SELECT and NEXT buttons to navigate and change the number on the display 5 To exit the Installer Menu press the MENU button The gate status appears in the display in...

Page 82: ...a notebook or if you have a laptop computer you can use HySecurity s START software and download the menu settings and save them to a file to upload to the operator at a later date NOTICE When you pr...

Page 83: ...ns and its monitoring capabilities This section explains how to z z Make connection on the Smart DC Controller z z Integrate with Security Systems z z Adapt User Relays for your Gate Site Figure 48 Sm...

Page 84: ...T IN OBS LOOP OUTOBS LOOP CENTER LOOP SENSOR COM 24V EMERG OPEN SHOW LEDs COMMON TERMINALS HY 5B FREE EXIT HY 5B INSIDE LOOP HY 5B OUTSIDE LOOP HY 5B CENTER LOOP RS 485 COMMUNICATION USB PORT USER REL...

Page 85: ...e of sight external stop button or 3 button station Open Open Normally Open N O input DO NOT use for radio or remote access controls Line of sight external open button or 3 button station Close Close...

Page 86: ...g loop Optional settings available Installer Menu item IR Outside Obstruction Loop Outside Obstruction Vehicle Detector N O input Inside reversing loop Optional settings available Installer Menu item...

Page 87: ...RG OPEN overrides photo eye edge sensor commands Do not connect an external control to STOP or OPEN inputs unless controls are located in clear view of entire gate area Use RADIO OPEN input or RADIO O...

Page 88: ...tus updates and control commands are easily integrated with a central controller computer or server which becomes the primary master to the connected operators Several physical operators 1 to 99 can b...

Page 89: ...l vehicle detectors are clear and no other open command is present Mode 2 The close timer does not wait for vehicle detectors to clear but instead it starts counting down as soon as the open limit is...

Page 90: ...troller z z Very low power draw which is important for maximum UPS capability during a power failure and for solar applications z z Cross talk between multiple loops is impossible z z Best operating f...

Page 91: ...Box Type Vehicle Detectors on page 93 5 Repeat Steps 1 through 3 for each HY 5B detector 6 To enable the detectors turn on power The detectors will immediately tune if they are connected to loops Make...

Page 92: ...r Configurable Functions Display Meaning Installer Menu Setting Options Bold Default OR 1 Outside Obstruction loop detector function 0 Pause closing only 1 Enable reverse to full open IR 1 Inside Obst...

Page 93: ...he Smart DC Controller 3 If multiple detectors are used route the power wires and common wire from socket to socket daisychaining rather than individually running each wire to the same location See Fi...

Page 94: ...tput becomes active when an open limit is triggered and deactivates when open limit is released or a close command is received Use this output for a traffic light 4 Open limit pulse output Triggers a...

Page 95: ...e made in Installer Menu 14 Gate nearing full travel output Activated when gate is approaching full open or full closed Relay activates three feet from where software expects limit switch to be trigge...

Page 96: ...ngSmart DC operator 32 Backoff Pulse Not functional in SwingSmart DC operator 33 Transient In Pulse Not functional in SwingSmart DC operator 34 Transient Out Pulse Not functional in SwingSmart DC oper...

Page 97: ...ator without regard to preference z z Be sure both operators are running the same software version The software version is available on the display by pressing the RESET button on the operator The sof...

Page 98: ...d Main power in 115 230VAC power conduit if required Conduit for Dual Gate wiring Conduit Conduit for Vehicle Detector wires may be shared with low voltage control wires PUBLIC SIDE SECURE SIDE 98 www...

Page 99: ...ield wire to only one operator not both Table 17 Primary Secondary Wiring Primary Secondary A A COM COM B B Only ground to one unit Do NOT attach the shield wire to both units Shield wire to Ground Fi...

Page 100: ...most often in a peer to peer relationship For example z z Any control input that is attached to secondary unit will be recognized by primary once Installer Menu is properly configured in both units NO...

Page 101: ...equenced gates Refer to Wire Diagram Interlocked Pair of Operators using DUAL GATE Wiring on page 77 Be sure to connect the wires in pairs to the same terminal ports A A B B COM COM on both operators...

Page 102: ...gister as an online member 4 Click to Download S T A R T software for Smart Touch and Smart DC 5 Read the End User License Agreement and if you agree to the terms click on I accept bottom of the page...

Page 103: ...utine maintenance is needed for the electrical system or controls If the environment is very sandy or dusty or has many insects be certain to seal all holes in the electrical enclosure Blow the dust o...

Page 104: ...the following z z Sweep debris out and away from the chassis z z Verify drive belt has proper tension Check for drive belt wear Fraying edges or missing teeth indicate that drive belt needs to be rep...

Page 105: ...is properly tensioned it should move about 1 16 to 1 8 inch 16 to 32 mm 5 To replace or re tension the drive belt Loosen the four motor bracket nuts and move the motor accordingly 6 With the belt prop...

Page 106: ...MX002008 50Ah MX002013 The batteries supplied in the SwingSmart operator are state of the art AGM batteries Do NOT use flooded cell batteries as damage may occur to the unit Wear protective clothing...

Page 107: ...and red terminals 3 As you slide the battery onto the tray connect the black wire to the black terminal on the right battery 4 Return the support tray to its original position and secure it properly...

Page 108: ...This terminal is the same as the input terminal labeled RADIO OPEN along the left edge of the Smart DC Controller 6 Mount an external antenna onto the top of a fixed fence post near the operator 7 Co...

Page 109: ...4VDC 24VDC 12VDC 12VDC A achthepowerwirefromthelock totheappropriatepowerspade ConnectCOMonboard toCOMonUSER1RELAY ConnecttheCOMwirefrom thelock ASolenoidlocka achestoNO AMagLocka achestoNC COM DUALGA...

Page 110: ...ccess and for Emergency Close z z Installing in ground vehicle loops with the option to set the Close Timer CT in the Installer Menu INSTALLING VEHICLE DETECTORS AND LOOPS A vehicle detector passes a...

Page 111: ...in cable is used Never route high voltage circuits in PVC conduit near a loop 5 Loopandlead inwireshouldbeonecontinuous piece Avoid splices if possible If a splice is necessary for any reason pot the...

Page 112: ...open and obstruction sensing logic only Because of their slower speeds closing logic is a poor choice for security gate systems Since there are several ways that the gate may be left standing open and...

Page 113: ...R T 10 I2C BUS ERROR HY 5B vehicle detector Communications alert Alert indicates detector is not communicating properly with Smart DC Controller Alert occurs if detector is unplugged or connection is...

Page 114: ...portion of the loop operational z z INFINITE never drops the call The INFINITE setting requires a certain amount of signal strength A threshold is maintained and it will hold the call forever The loop...

Page 115: ...luable because it provides information about how well the loop is actually seeing a specific vehicle For example it may be useful to check to see if the loop is easily detecting the middle of a high b...

Page 116: ...EXIT loop is replaced by an OBSTRUCTION loop the FREE EXIT loop is replaced by an OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or OBSTRUCTION LOOP NOTE A minimum of three 3 detectors ar...

Page 117: ...TION loop the FREE EXIT loop is replaced by an OBSTRUCTION loop SECURE SIDE C D E F CENTER LOOP FREE EXIT or OBSTRUCTION LOOP NOTE A minimum of three 3 detectors are required for this type of gate DIM...

Page 118: ...ensor inputs are available for use and must be programmed to a non zero number when initial configuration is performed The three inputs are labeled Sensor 1 Sensor 2 and Sensor 3 and are configurable...

Page 119: ...al for monitoring and powering purposes The sensor becomes actively powered when the gate operator s motor runs CAUTION Connect all contact and non contact sensors to same power source Example Do NOT...

Page 120: ...s recommended one photo eye to guard the open direction and the other for the close direction of travel unless gate edges for entrapment protection are installed z z Three wires to the receiver and tw...

Page 121: ...t to 0 the next time the Close Limit Switch is triggered or the RESET key is pressed Notes about retro reflective systems Correct installation and alignment of a retro reflective photo eye and its ref...

Page 122: ...oller Installer Menu Functions on page 68 for more information REFERENCE INSTALLING GATE SENSORS ON SWING GATES Three sided sensors are ideal for swing gates If gate clearance is 4 inches 10 cm or mor...

Page 123: ...tact opens Additionally if communication between transmitterandreceiveriseverlostorcorrupted due to too much RF noise in area then the receiver will indicate to control board that the edge is tripped...

Page 124: ...ready in Safe Mode Operator will not function until it is reset which can occur by z z An Open or Stop command from a push button control z z Pressing black button on operator side z z Pressing RESET...

Page 125: ...ries are 90 depleted Gate will automatically open or close depending upon setting chosen No additional automatic function is possible but limited push button control is available to 18V Refer to corre...

Page 126: ...s if gate drifts three times in a five minute period Check track to make sure it is level ALERT 4 MOTOR OVERLOAD Thermal overload alert When alert is triggered gate can only fully open until alert is...

Page 127: ...Center Loop CLD User Relay 22 Loop lead in wires and roadway should be checked for problems or replaced ALERT 8 LOOP SHORTED H Y 5 B h a s d e t e c t e d a loopshorted to ground Caused by inadequate...

Page 128: ...e Obstruction Loop OOLD or Center Loop CLD User Relay 22 Check traffic patterns at site Loop and lead in wires should be checked for problems or replaced ALERT 13 STIFF GATE S m a r t D C Controller h...

Page 129: ...ed to be replaced Batteries are not taking a charge properly Buzzer will chirp every minute until UPS batteries are replaced ALERT 19 FALSE SLOWDOWN Not used with DC operators Not used with DC operato...

Page 130: ...ALERT 22 appears access Installer Menu Verify Installer Menu items DG Dual Gate and SG Sequential Gate are both set to zero ALERT 24 EXTERNAL RELAY FAULT Communication Lost with Hy8Relay module Appear...

Page 131: ...there is no load on operator Gate is non operational while this fault is triggered Possible causes z z Motor wires disconnected z z DC switch off z z Linkage failure z z Taper clamp being too loose 1...

Page 132: ...ectly See Primary and Secondary Wiring Connections z z Primary Secondary not configured properly through Installer Menu z z Operator not properly Operator not properly earth grounded z z Primary Secon...

Page 133: ...uire factory reset Corrupt software or data C a l l H y S e c u r i t y Technical Support for assistance ERROR 8 RPM SENSOR RPM sensor disconnected Motor Encoder or wires are damaged or unplugged Chec...

Page 134: ...ator Failure to adjust and retest the gate operator properly can increase the risk of injury or death 4 V ri ez le fonctionnement de l ouvre barri re une fois par mois Le sens de la course DOIT s inve...

Page 135: ...ate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate L ouvre barri re est destin n tre install que sur des barri res utilis es...

Page 136: ...uette doit tre visible des personnes situ es de chaque c t de la barri re sur laquelle l tiquette est install e For gate operators utilizing a non contact sensor Pour les ouvre barri res qui fonctionn...

Page 137: ...e barri re pour pr venir le coincement doit tre situ un endroit o la transmission des signaux ne sera pas obstru e ou g n e par des structures des arbres ou d autres obstacles similaires Un dispositif...

Page 138: ...NOTES 138 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...

Page 139: ...NOTES 139 www hysecurity com SWINGSMART DC PROGRAMMING AND OPERATIONS MANUAL MX3640 01 REV D 2018...

Page 140: ...d to negligence accident vandalism or damaged by severe weather wind flood fire terrorism or war or 3 damaged through improper operation maintenance storage or abnormal or extraordinary use or abuse A...

Reviews: