Table 12. Smart DC Controller - Installer Menu Functions
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
Associated
DC Controller
Display
Connections
DG 0 (OFF)
Dual Gate
0 = solo operator
1 = Secondary unit
2 = Primary unit
3 = Sally Port A
4 = Sally Port B
Configures gate operator as a Primary
or as a Secondary in a dual-gate
installation. When you assign one unit
as Primary, you must configure other as
Secondary through Installer Menu. This
menu is also used to configure a Sally
Port system by setting one operator to
Sally Port A and the other to Sally Port B.
3-wire
shielded cable
to DUAL
GATE input
terminals.
Connect Dual
Gate COM
(Gate 1) to
Dual Gate
COM (Gate 2).
Pair wires:
A - A, COM
- COM, and
B - B
SG 0 (OFF)
Sequenced Gate
0 = solo operator
1 = Loop View #1
2 = Loop View #2
3 = Loop View #3
4 = Loop View #4
Establishes communication after wiring
two or more gate operators as sequential
gates. This SG menu item only appears
if the Dual Gate menu item (DG) is set
to 0 (solo operator).
NOTE:
After selecting SG settings,
consider accessing the User Menu in
each gate operator to address the Close
Timer (CT) setting.
3-wire
shielded cable
to DUAL
GATE input
terminals
on both
operators. Pair
wires: A - A,
COM - COM,
and B - B
CH 0 (AC)
Charger Type
0 = AC powered
1 = Solar powered
Assigns charger type usually set at
factory. If set to solar at factory then this
menu item is hidden.
(N/A)
BT 0 (STANDARD)
Battery Type
0 = standard (8Ah)
1 = extended
(50Ah)
2 = maximum
(110Ah)
Assign battery type used by operator.
NOTE:
Smaller batteries are charged
with less current to avoid overheating
and larger batteries are charged with
more current to supply a more rapid
charge.
Extended
(50Ah)
batteries
require wire
extensions.
Maximum
(110Ah)
batteries
require
separate
housing and
wiring.
DISPLAY AND MENU OPTIONS