Do System Tests to Identify Defective Components
5
76
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
System tests in this section
How to attach to ground
For tests where it is necessary to attach the multimeter to ground, use the ground screw on the
heatsink.
System test
Associated fault codes
0-60-
n
3-43-0
3-51-1, 3-52-0
Test 4 – Inverter thermal sensor and PFC temperature sensor
on page 91 0-40-
n
, 2-10-
n
, 3-11-
n
Test 5 – Flyback circuit (DC minor voltages)
3-00-0, 3-42-
n
, 3-43-
n
Test 6 – Torch stuck open (TSO) or torch stuck closed (TSC)
on page 98 0-30-
n
0-51-0, general
0-50-0
Test 9 – Solenoid valve electronic regulator
0-21-0, 3-20-
n
Test 10 – Solenoid valve pressure sensor
0-12-0, 0-20-0, 0-22-0, 2-11-
n
0-40-
n
, 3-10-
n
Test 12 – Auxiliary (AUX) switch
2-01-0 or unreported interlock at
START
General
Test 14 – Radio Frequency (RF) communication errors
0-98-1, 0-98-2
J27
WORK
LEAD
J26
J25
+
_
+
_
J25
Summary of Contents for Powermax105