Do System Tests to Identify Defective Components
5
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
81
Figure 11
– Powermax105 SYNC
5.
If the diode bridge output value is correct, but you continue to get an 0-60-
n
fault code, do the
following:
a.
Go to the
POWER SUPPLY DATA
screen.
b.
Make sure that the value in the
VL
field is ±15% of the AC line voltage.
3-phase
L1
Black (CSA)
Brown (CE/CCC)
L2
White (CSA)
Black (CE/CCC)
L3
Red (CSA)
Gray (CE/CCC)
PE
Green (CSA)
Green/yellow (CE/CCC)
LV/1.732
Black wire
Ground
(GRD)
LV
LV
LV
LV X
1.414
LV/1.732
LV/1.732
LV = incoming line voltage