Troubleshooting for Fault Codes
3
58
810430
Troubleshooting Guide
Powermax65/85/105 SYNC
2-11-0
Yellow
Red
The pressure sensor is open.
• Examine the related wiring.
Test 10 – Solenoid valve pressure
2-11-1
The pressure sensor
short-circuited.
2-20-0
Yellow
Red
The DSP PCB does not
recognize the torch.
• Make sure that the torch lead is correctly
connected to the FastConnect receptacle
on the front of the plasma power supply. Do
a quick restart.
• Examine the FastConnect receptacle to
make sure that the pin-out is correct. Refer
to
Also refer to the wiring diagram for your
system, starting on
Fault
code
Fault
icon
Fault
LEDs
Description
Solutions