Prepare to Troubleshoot Internal Components
2
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
25
Do a check for continuity
For some torch-related faults, you can do a check for continuity between the following test points to
identify if the problem is with the plasma power supply. If there is no continuity between any of these
points, replace the quick-disconnect receptacle.
Table 1
– Continuity test points in the plasma power supply
Table 2
– Continuity test points in the plasma power supply
Quick-disconnect receptacle
J20 or J17 on the power PCB*
Wire color
5
1
Blue
6
3
Violet
7
2
Orange
8
9
Black
9
7
Brown
10
8
Gray
11
4
Yellow
12
5
White
13
6
Red
* J20 on Powermax65/85 SYNC / J17 on Powermax105 SYNC.
8
7
6
5
4
3
2
1
J20 / J17
BLU
ORG
VIO
YEL
WHT
RED
BRN
GRY
9
BLK
BLK
BLK
1
2
3
4
5
BLU
6
VIO
7
ORG
8
BLK
9
BRN
10
GRY
11
YEL
12
WHT
13
RED
14
15
16
17