Do System Tests to Identify Defective Components
5
Powermax65/85/105 SYNC
Troubleshooting Guide
810430
123
Test 12 – Auxiliary (AUX) switch
Use this test if you see one of these conditions:
The main screen is blank after you set the plasma power supply to ON.
The 2-01-1 fault code shows.
This test is not applicable for Powermax65/85 SYNC CE/CCC models.
1.
Set the power switch on the plasma power supply to OFF (
O
), and disconnect the power cord.
2.
Remove the plasma power supply cover and the component barrier.
3.
Powermax65/85 SYNC CSA:
Disconnect the auxiliary switch cable
from J1 on the power PCB.
Powermax105 SYNC:
Disconnect
the auxiliary switch cable from J5 on
the power PCB.
4.
With the power switch on the plasma
power supply set to OFF (
O
),
measure the resistance between
pin 4 and pin 5 on the auxiliary
cable’s connector. Refer to
on page 124. If there is high
resistance between the pins, do a
check for an open circuit or a short
circuit on the auxiliary switch
receptacle on the power PCB and on the power switch.