MAXPRO200
Instruction Manual 807700 Revision 1
35
Specifications
Cooling system
The cooling system uses a liquid-to-air cooled heat exchanger and a pump to reduce the temperature of the coolant. The
coolant cools the chopper, torch lead and torch. The cooling system also contains flow and temperature sensors that
verify the cooling system is working properly.
System gas requirements
Gas quality and pressure requirements
Gases
Quality
Pr/- 10%
Flow rate
O
2
oxygen
99.5% pure (liquid gas recommended)
Clean, dry, and oil free
621 kPa / 6.2 bar / 90 psi
3400 l/h 120 scfh
N
2
nitrogen
99.9% pure (liquid gas recommended)
Clean, dry, and oil free
621 kPa / 6.2 bar / 90 psi
11330 l/h 400 scfh
Air
Clean, dry, and oil free (ISO 8573-1 class 1.4.2)
621 kPa / 6.2 bar / 90 psi
11330 l/h 400 scfh
Gases by process
Mild steel
Stainless steel
Aluminum
Amperage
Plasma gas
Shield gas
Plasma gas
Shield gas
Plasma gas
Shield gas
Cutting 50 A
Air or O
2
Air
Air
Air
Air
Air
Cutting 130 A
Air or O
2
Air
Air
Air
Air
Air
Cutting 130 A
N
2
N
2
N
2
N
2
Cutting 200 A
Air or O
2
Air
Air
Air
Air
Air
Cutting 200 A
N
2
N
2
N
2
N
2
Summary of Contents for MAXPRO200
Page 1: ...MAXPRO200 Instruction Manual 807700 Revision 1 ...
Page 26: ...22 MAXPRO200 Instruction Manual 807700 Revision 1 Safety ...
Page 34: ...30 MAXPRO200 Instruction Manual 807700 Revision 1 Product Stewardship ...
Page 38: ...34 MAXPRO200 Instruction Manual 807700 Revision 1 Specifications ...