The following picture shows an example of a cutting table ground bus. The components shown here may differ from your
system.
The following picture shows an example of a gantry ground bus. It is bolted to the gantry, close to the motor. All of the
individual ground cables from the components mounted on the gantry go to the bus. A single heavy cable then goes from
the gantry ground bus to the table ground bus,
The following diagram shows an example of grounding the components in a plasma cutting system.
5
4
3
2
6
7
1
Gantry ground bus
2
Ground rod
3
Plasma system lead (+)
4
Remote high frequency (RHF) console
5
CNC enclosure
6
Torch holder
7
Plasma system chassis
1
2
1
1
Cable to the cutting table ground bus
2
Ground cables from components on the gantry