Operation
Choosing a cutting process
1.
Use the current selection knob to set the amperage. Turning the knob slowly increases or decreases the current
1 amp at a time. Turning the knob fast lets you jump quickly to the next process current (50A, 130A, and 200A).
A blinking red dot appears in the bottom right corner of each display when the parameters have been changed from
the default setting. You can return to the default setting by pressing and releasing the knob until you return to the
original selection.
2.
Push and release the plasma gas knob to cycle through the plasma gas selections. The pressure will automatically be
set when you choose a gas. Turning the knob increases or decreases the pressure. A blinking red dot appears in the
bottom right corner of each display when the parameters have been changed from the default setting. You can return
to the default setting by pressing and releasing the knob until you return to the original gas selection.
3.
The shield gas pressure is set automatically when you choose a plasma gas. Turning the knob increases or decreases
the pressure. A blinking red dot appears in the bottom right corner of each display when the parameters have been
changed from the default setting. You can return to the default setting by pressing and releasing the knob until you
return to the original gas selection.
Note:
The example shown below is the 50 amp, mild steel, air/air process. See the cut chart for details.
1
2
3
Summary of Contents for MAXPRO200
Page 1: ...MAXPRO200 Instruction Manual 807700 Revision 1 ...
Page 26: ...22 MAXPRO200 Instruction Manual 807700 Revision 1 Safety ...
Page 34: ...30 MAXPRO200 Instruction Manual 807700 Revision 1 Product Stewardship ...
Page 38: ...34 MAXPRO200 Instruction Manual 807700 Revision 1 Specifications ...