Preventive maintenance
4
92
811390
Operator Manual
DynaMAX 550P/560P/575P Waterjet Pump
The 1-micron and the 10-micron filters do not have a designated top or bottom.
7.
Install the filters and the housings with the 10-micron water filter nearest the rear of the pump.
8.
Discard the used parts.
9.
Use a filter wrench to tighten each of the filter canisters.
10.
Close the water valve.
11.
Turn
ON
the water to the pump.
12.
Turn
ON
the pump in cooling mode.
13.
Push the water filter purge buttons until water comes out from under each button.
14.
On the operator interface, touch the
RUN
symbol.
15.
Make sure that the difference between the values on the prefilter water-pressure gauge and the
postfilter water-pressure gauge is lower than 0.7 bar (10 psi).
1
2
3
1
10-micron water filter
2
1-micron water filter
3
0.22-micron water filter
Summary of Contents for DynaMAX 550P
Page 1: ...DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 REVISION 0 ENGLISH...
Page 16: ...Product stewardship 16 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 46: ...Optional equipment 2 46 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 64: ...Operation 3 64 811390 Operator Manual DynaMAX550P 560P 575P Waterjet Pump...
Page 136: ...Preventive maintenance 4 136 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 146: ...Parts lists 5 146 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 172: ...Troubleshooting 6 172 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 222: ...Technical drawings 10 222 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 223: ...Technical drawings 10 DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 223...