Make sure that the heat exchanger fan motor turns in the correct direction
1.
Operate the pump until the fan turns on.
2.
Make sure that the fan motor turns in the direction shown by the rotation arrow.
If the fan motor turns in the wrong direction
a.
Disconnect the electrical power to the pump.
b.
In the electrical enclosure, interchange 2 wires on the bottom of the motor starter.
Turn on the pump
1.
Set the pressure to 345 bar (5,000 psi).
2.
On the operator interface, touch the
C
OOLING
MODE
symbol to turn
ON
the pump.
3.
Let the pump operate for 2 to 3 minutes.
4.
Monitor for leaks.
CAUTION
A leak can cause damage to the water fittings.
Identify the source of a leak and correct the problem.
Summary of Contents for DynaMAX 550P
Page 1: ...DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 REVISION 0 ENGLISH...
Page 16: ...Product stewardship 16 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 46: ...Optional equipment 2 46 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 64: ...Operation 3 64 811390 Operator Manual DynaMAX550P 560P 575P Waterjet Pump...
Page 136: ...Preventive maintenance 4 136 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 146: ...Parts lists 5 146 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 172: ...Troubleshooting 6 172 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 222: ...Technical drawings 10 222 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 223: ...Technical drawings 10 DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 223...