57
If the difference between the values is more than 0.7 bar (10 psi), replace the water filter.
Check the hydraulic filter gauge
Do this task when the pump is operating at a stable temperature.
Make sure that the indicator on the hydraulic gauge is not in the red zone.
Check the hydraulic fluid level
Do this task when the pump is operating.
Make sure that the hydraulic fluid level is at the top mark on the sight gauge. Add hydraulic fluid, if
necessary.
Do this task every work shift.
Replace the hydraulic filter element:
• every 1,500 hours.
• when the indicator on the gauge stays in the red zone while the pump is operating.
Do this task every work shift.
1
2
3
1
Filter-breather cap
2
Sight gauge
3
Drain valve
Summary of Contents for DynaMAX 550P
Page 1: ...DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 REVISION 0 ENGLISH...
Page 16: ...Product stewardship 16 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 46: ...Optional equipment 2 46 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 64: ...Operation 3 64 811390 Operator Manual DynaMAX550P 560P 575P Waterjet Pump...
Page 136: ...Preventive maintenance 4 136 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 146: ...Parts lists 5 146 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 172: ...Troubleshooting 6 172 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 222: ...Technical drawings 10 222 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 223: ...Technical drawings 10 DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 223...