![Hypertherm DynaMAX 550P Operator'S Manual Download Page 53](http://html1.mh-extra.com/html/hypertherm/dynamax-550p/dynamax-550p_operators-manual_2193802053.webp)
Operation
3
DynaMAX 550P/560P/575P Waterjet Pump
Operator Manual
811390
53
Check the hydraulic fluid quality
1.
Look through the sight gauge to see the color of the hydraulic fluid. Good hydraulic fluid is
almost transparent.
2.
Remove the filler-breather cap on top of the tank.
3.
Smell the hydraulic fluid. Good hydraulic fluid has almost no odor.
4.
Install the filler cap.
Replace the hydraulic fluid:
• every 3,000 hours.
• if it is dark or milky in color.
• if it has a strong odor.
• if a test laboratory finds the quality is unsatisfactory.
CAUTION
Heat and other conditions cause hydraulic fluid to degrade. Degraded hydraulic fluid can
cause damage to hydraulic components.
on page 174 for recommended temperature limits.
Collect a sample of hydraulic fluid from the hydraulic fluid tank and send it to a test
laboratory for analysis.
Contact a hydraulic fluid supplier for a precise report about the hydraulic fluid quality.
Summary of Contents for DynaMAX 550P
Page 1: ...DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 REVISION 0 ENGLISH...
Page 16: ...Product stewardship 16 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 46: ...Optional equipment 2 46 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 64: ...Operation 3 64 811390 Operator Manual DynaMAX550P 560P 575P Waterjet Pump...
Page 136: ...Preventive maintenance 4 136 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 146: ...Parts lists 5 146 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 172: ...Troubleshooting 6 172 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 222: ...Technical drawings 10 222 811390 Operator Manual DynaMAX 550P 560P 575P Waterjet Pump...
Page 223: ...Technical drawings 10 DynaMAX 550P 560P 575P Waterjet Pump Operator Manual 811390 223...