Page 14
4.5 Main components
4.5.1 The system cabinet and its
installations
4.5.1.1 Pump station
The vane pump generates a pressure of up
to 15 bar. The maintenance-free variable fre-
quency-driven asynchronous motor enables
continuous operation up to 50 Hz. Depend-
ing on the speed of the pump, water
pressure and, consequently, the amount of
atomized water may be varied. Water pres-
sure is in the range from 5 to 15 bar allowing
for the optimum mix of throughput and aero-
sol size.
view diagonally
from the left
1
2
3
4
5
6
7
8
9
11
10
12
1 Operating panel with display
7 1¼“ wastewater drain connection, free
running
2 Control switch
8 Water inlet solenoid
3 Electronical control unit
9 ¾
“
supply water connection
4 Frequency converter
10 Solenoid for flushing
5 Main contactor
11 Solenoid for nozzle segments
6 Motor pump
12 Outlets to nozzles, may be mounted on
the cabinet top as well (mounting mate-
rial included in delivery)