User Guide Oxymatic Basic
Rev.Apr 2013
Hydrover Water Solutions S..L.U.
12
Connection cables for titanium or copper electrodes
NOTE: Ensure that the cables are connected to the corresponding terminals:
1.
30 – 31 oxidation; to the Titanium electro holder
2.
32 – 33 ionization, to the Copper electro holder
Connections to the temperature probes, pH injections and injections pump.
For installation of the pH sound chamber and the injection canal the included probe holder should be used.
Please then proceed in the order shown in the photo below:
ATTENTION: The pH injection canal must be positioned at the end of the water circuit to avoid acid making
contact with the electrodes or other components i.e .filter, water pump, heat pump, exchangers. Contact could
cause damage/deterioration.
NOTE: Once the connections have been verified, connect the Oxymatic to the outlet and using the MODE button
press AUTO. The equipment will now commence operating.
Injectors
Temperature Sensor
(Advanced model only)
Rx Probe Adv. Model only
Pump
pH Probe