User Guide Oxymatic Basic 

Rev.Apr 2013 

 

Hydrover Water Solutions S..L.U.

 

19

 

7.

 

MAINTENANCE

 

6.1. Table of Maintenance and control 

From now on, the only thing needed is the maintenance of the equipment and checking the below parameters: 

 
IMPORTANT:   In order for the Titanium electrodes (Ti) to work 100% effectively and to avoid deterioration, they 
should work at only 9.5 v,  otherwise its life expectancy will be only a few months. The GUARANTEE does not 
cover the deterioration of the electrodes. The voltage should be measured weekly. 
 

6.2. Cleanliness of the electrodes and duration 

Visually, you should ensure that there is not too much  dirt  between  the  internal  spaces  of  each  pair  of 
electrodes. As soon as you see that they are dirty, disconnect the cables, unwind the chambers and submerge 
them for 10 minutes in 50% vinegar and 50% water and delicately brush them with a tooth brush so as not to 
damage the patented lining that the electrodes have. Never use a metallic brush as this will seriously damage 
the electrodes  and they will no longer work. 
 
Remember that the cables that are connected to the titanium electrodes are the cables that come out of the 
control unit if we are stood in front of it, and the cables that lead to the copper electrodes are connected to the 
fifth or last port from the left. 
 
 The average frequency of cleaning depends on the water quality and quantity of flocculent used. 
 
The average frequency of the cleanliness will depend on the water quality and the quantity of used flocculating 
agent.7. Visually check the electrodes every month and clean them when you see dirt between them. 
  

NOTE: Remember to check the parameters of calcium hardness, alkalinity, TDS (total dissolved solids), pH and 
residual  copper.  The  more  professionally  monitored  the  better  (at  least  once  a  month,  depending  on  water 
losses and filling), this way the water is best disinfected. It will prevent damage to the components of the pool 
(including the electrodes) and avoid inconvenience to bathers. This is independent of the disinfection system 
used (chlorine, bromine, ozone, OXYMATIC, etc ...), and little by little, owing to the swimmers, filtration and 
washing of filters, microorganisms from the water, filled with fresh water, sun , etc ..., change the parameters of 
the water. 
 

8.

 

INCOMPATIBILITIES AND POSSIBLE PROBLEMS WITH THE 

SYSTEM OXYMATIC  

 
ATTENTION: the disinfection system by oxygen and mineral ions, OXYMATIC, is fully compatible with others such 
as chlorine, bromine, active oxygen, etc ... 
 

7.1

 

Probes of chlorine copper-platinum amperometric probes.  

In some cases it was found that the copper ions created by the OXYMATIC system have caused some kind of 
interference in the reading of these probes. It is recommended that Platinum or Gold-Platinum-Gold probes are 
used using an amperometric chlorine sensor

 

PARARAMETER 

   RECOMMENDED 

DATA 

INCREASE 

REDUCE 

CONTROL 

pH 

  

6.8 to 7.2 

  

Add pH increaser liquid 

  

 Add pH reducer  Liquid  

Sulphuric acid (dilute 38%) 

(H

2

SO

4

) better than  

hydrochloric dilute acid (HCl) 

Automatic  pH 

Regulador  

  

Copper (ppm) 

  
  

0.4 – 0.7 

  

  

Increase the time of 

ionization or add copper 

sulphate 

Dilute a portion of the pool 

water and reduce the operation 

time of the Ionization. 

Weekly 

  
  

H

2

O

2

 (ppm) 

10 – 20

 

Hydrogen peroxide 

(H2O2). Increase 

minutes per day dosing. 

Decrease minutes or renew 

daily dosing of the pool water 

Weekly 

 Voltage (V) to Ti 

electrodes 

  

< 12 Vac 

  

  

IF < 9.5 V do nothing 

  
  

Increase the conductivity of the 

water by adding SALT in the 

water  (NaCl) 

Weekly 

  
  

Summary of Contents for Oxymatic

Page 1: ...BASIC Installation Programming and Maintenance User Guide...

Page 2: ...ONS Summary 1 INTRODUCTION 3 2 CONTENT 6 3 OXYMATIC SYSTEM INSTALLATION 8 4 OXYMATIC START 13 5 PRESENTATION OF OXYMATIC BASIC 15 6 INSTALLATION AND PUTTING IN MARCH STEPWISE 18 7 MAINTENANCE 19 8 INC...

Page 3: ...U S Registered Center for Disease Control recognizes Chloroform and dioxin two bi products of chlorination as toxic Growing awareness and concerns to the environment and human health due to the use of...

Page 4: ...maximum temperature of approximately 50 C The aforesaid avoids the fouling inside the pipe and reduces the tendency to corrosion This phenomenon was tested by ETL Laboratories EPA and developed by OX...

Page 5: ...mus 1 00 Miscellaneous Spirogyra 0 12 Chara 0 10 0 50 Starastrom 1 50 Nitella flexilis 0 10 0 18 Ulothrix 0 20 Potamogeton 0 30 0 80 Volvox 0 25 Diatomeas Zygnema 0 60 Asterionella 0 12 0 20 Fragilari...

Page 6: ...User Guide Oxymatic Basic Rev Apr 2013 Hydrover Water Solutions S L U 6 2 OXYMATIC CONTENT 2 1 Included Items...

Page 7: ...olutions S L U 7 2 2 Excluded Items NOT INCLUDED but necessary for installation Adhesives PVC pipes By pass valves Motor Protection Fastening screws Oxymatic 2 3 Dimensions oxymatic Length 29 cm Depth...

Page 8: ...atic system this is the basis of a good installation It is important that the camera is installed after the filtering circuit and heating see diagram below The titanium electrodes should be connected...

Page 9: ...lectricity The equipment is shipped ready for use via 100v to 240v There is no requirement for a power adapter but we recommend installing a motor protector before connecting to the mains This avoids...

Page 10: ...connections that are permitted via Oxymatic N Conector Descripci n 1 y 2 Connecting the pH injection pump 24V 5 6 y 7 Main power connection to the network Max 240V 8 14 Connections indicators 15 16 F...

Page 11: ...an Hydrover will not take any responsibility for any modifications made by an individual that result in lack of functionality or damage to the system Any necessary call outs by a technician or any tec...

Page 12: ...and the injection canal the included probe holder should be used Please then proceed in the order shown in the photo below ATTENTION The pH injection canal must be positioned at the end of the water...

Page 13: ...ganisms bacteria materials or heavy metals In this case the water needs an intensive preparation before the OXYMATIC system is operational The water must be completely free of metals bacteria etc Elec...

Page 14: ...4 or 5 years The Zeobrita saves 50 water in washing the filter 4 1 3 Adjustment of the copper It is necessary to measure the copper disuelto within the water with a colorimetric meter If the level of...

Page 15: ...LARM FUNCTIONS OFF FLOW SWITCH MANUAL HANDLING KEYS POSITION VOLTAGE TITANIUM ELECTRODES FUNCTION OXYDATION BAD AMP VOLTAGE MEDIUM VOLTAGE AMP GOOD AMP VOLTAGE REGULAR AMP VOLTAGE FUNCTION PER CL PERI...

Page 16: ...elow 100 it is recommended to add sea salt table salt to the pool to increase the conductivity of the water and raise the amperage This way it reduces the voltage of the electrodes of titanium b Ioniz...

Page 17: ...computer in the manual position 3 Press the SOL 2 light comes on 4 Press the OK in light of the position set point 100 will turn next to the SOL1 and SOL 2 5 Press the Sol 1 to lower the set point 10...

Page 18: ...rred location 3 The hang rhe dosing pump oh pH close to the chamber and above the container of pH reductor 4 To put the electrodes in order of entry and exit carefully When the glue is dry 5 The recir...

Page 19: ...member to check the parameters of calcium hardness alkalinity TDS total dissolved solids pH and residual copper The more professionally monitored the better at least once a month depending on water lo...

Page 20: ...p water and gently dry especially the end part where the membrane is NOTE Clean and dry the pH probe before inserting it into the buffer solution 2 The membrane of the pH probe which is in the end sho...

Reviews: