4.1.1.

 

Water totality disinfected (very impoirtant)) 

It  is  important  that  before  activating  the  OXYMATIC  system that the water is totally disinfected.  When 
functioning, the system is capable of keeping water in pristine condition but it cannot disinfect water that is 
green with algae. It is therefore important, should the water contain algae, bacteria and pathogens to carry out a 
shock treatment as follows:  
 
To make an effective shock treatment, water pH should be below 7.5. If not, adjust (see parameter table).  
 
Add required dose of disinfectant chlorine, bromine active oxygen to enhance the shock treatment. Follow the 
specifications of the product sold at your local retailer, then place in the nozzles and around the pool. Using 
rapid dissolution products maybe a preferred option e.g. chlorine fast 
 
Once having added the chemical of your choice keep the pumps of the pool operating for 12 hours so that the 
chemicals are recycling.  It is recommended you carry out this operation during the night to minimize the 
evaporation of the disinfectant.  
 
Turn off the pump. 
 
Add flocculants. We recommend using small sacks that are placed in the skimmer, or flocculants liquid directly 
on the glass of the pool. 
 
Leave about 6-10 hrs until deposits are formed at the bottom. 
 
Pass the clean-funding to eliminate the dirty water full of flocs (NO Re-circulating). 
 
Filter wash. 
 

4.1.2.

 

Filtre backwash 

Filter backwash - this process will clean the filter, removing all waste previously held by the filter. Consult the 
manual if necessary. 
 
NOTE: Use the Zeobrita (zeolite, volcanic rock) in replacing the sand filter. You'll get a leak between 2 and 5 
microns instead of 40 microns which filters the sand. It should be changed every 4 or 5 years. The Zeobrita 
saves 50% water in washing the filter. 
 

4.1.3.

 

Adjustment of the copper 

It is necessary to measure the copper disuelto within the water with a colorimetric meter.  If the level of copper 
is between 0.5-0.7 ppm the OXYMATIC system can be started however, if the copper level is over 0.7 ppm it will 
be necessary to reduce the levels.  If the level of copper is below 0.5 ppm it will be necessary to increase the 
copper – see two options to carry this out below:   
 
Option 1 (recommended by Hydrover): 

-

 

Start the equipment Oximatic in manual switching position  

-

 

The electrode of copper  set to work only (to see paragraph 4.3.1)  

-

 

To leave the equipment working 48 followed hours  

-

 

measure again the copper. 

-

 

Leave the system working for the number of hours necessary to achieve the recommended levels. 

 
Option 2:   

-

 

To dissolve in the swimming pool Sulfate of Copper in powder. The recommended dose is 0,5 g for 
every 1 m3 (50 g in a swimming pool of 100 m3) to obtain a proportion of 0,5 ppm in the water.  

-

 

To dilute the necessary amounts in a container and to distribute it within the swimming pool  

-

 

Measure copper levels 12 hours after distribution 

-

 

In the event of the required levels not being achieved repeat the process proportionately   

 
The ión Charges, CU2 + is a powerful agent of algicida and bactericidally. In concentrations below 0.4 ppm, it 
loses efficiency, and over 0.7  can stain  the glass of the swimming pool. In addition value of pH over 7.5-7.6 
favor the rainfall of any metallic ión that exists in the water. Generated this way stain of different colors green - 
bluish, black and brown can appear. 
  
IMPORTANTLY:  This  adjustment  only  has  to  be  carried  out  when the system is activated since the Oxymatic 
takes charge supporting the suitable level of copper in the water. The dosing recommended (0,5 and 0,7 ppm) 
There should be no health concerns  since according to the WHO (World Health Organization) a water is 
drinkable with a content level of up to 2 mg/l of copper. 

 

Summary of Contents for Oxymatic

Page 1: ...BASIC Installation Programming and Maintenance User Guide...

Page 2: ...ONS Summary 1 INTRODUCTION 3 2 CONTENT 6 3 OXYMATIC SYSTEM INSTALLATION 8 4 OXYMATIC START 13 5 PRESENTATION OF OXYMATIC BASIC 15 6 INSTALLATION AND PUTTING IN MARCH STEPWISE 18 7 MAINTENANCE 19 8 INC...

Page 3: ...U S Registered Center for Disease Control recognizes Chloroform and dioxin two bi products of chlorination as toxic Growing awareness and concerns to the environment and human health due to the use of...

Page 4: ...maximum temperature of approximately 50 C The aforesaid avoids the fouling inside the pipe and reduces the tendency to corrosion This phenomenon was tested by ETL Laboratories EPA and developed by OX...

Page 5: ...mus 1 00 Miscellaneous Spirogyra 0 12 Chara 0 10 0 50 Starastrom 1 50 Nitella flexilis 0 10 0 18 Ulothrix 0 20 Potamogeton 0 30 0 80 Volvox 0 25 Diatomeas Zygnema 0 60 Asterionella 0 12 0 20 Fragilari...

Page 6: ...User Guide Oxymatic Basic Rev Apr 2013 Hydrover Water Solutions S L U 6 2 OXYMATIC CONTENT 2 1 Included Items...

Page 7: ...olutions S L U 7 2 2 Excluded Items NOT INCLUDED but necessary for installation Adhesives PVC pipes By pass valves Motor Protection Fastening screws Oxymatic 2 3 Dimensions oxymatic Length 29 cm Depth...

Page 8: ...atic system this is the basis of a good installation It is important that the camera is installed after the filtering circuit and heating see diagram below The titanium electrodes should be connected...

Page 9: ...lectricity The equipment is shipped ready for use via 100v to 240v There is no requirement for a power adapter but we recommend installing a motor protector before connecting to the mains This avoids...

Page 10: ...connections that are permitted via Oxymatic N Conector Descripci n 1 y 2 Connecting the pH injection pump 24V 5 6 y 7 Main power connection to the network Max 240V 8 14 Connections indicators 15 16 F...

Page 11: ...an Hydrover will not take any responsibility for any modifications made by an individual that result in lack of functionality or damage to the system Any necessary call outs by a technician or any tec...

Page 12: ...and the injection canal the included probe holder should be used Please then proceed in the order shown in the photo below ATTENTION The pH injection canal must be positioned at the end of the water...

Page 13: ...ganisms bacteria materials or heavy metals In this case the water needs an intensive preparation before the OXYMATIC system is operational The water must be completely free of metals bacteria etc Elec...

Page 14: ...4 or 5 years The Zeobrita saves 50 water in washing the filter 4 1 3 Adjustment of the copper It is necessary to measure the copper disuelto within the water with a colorimetric meter If the level of...

Page 15: ...LARM FUNCTIONS OFF FLOW SWITCH MANUAL HANDLING KEYS POSITION VOLTAGE TITANIUM ELECTRODES FUNCTION OXYDATION BAD AMP VOLTAGE MEDIUM VOLTAGE AMP GOOD AMP VOLTAGE REGULAR AMP VOLTAGE FUNCTION PER CL PERI...

Page 16: ...elow 100 it is recommended to add sea salt table salt to the pool to increase the conductivity of the water and raise the amperage This way it reduces the voltage of the electrodes of titanium b Ioniz...

Page 17: ...computer in the manual position 3 Press the SOL 2 light comes on 4 Press the OK in light of the position set point 100 will turn next to the SOL1 and SOL 2 5 Press the Sol 1 to lower the set point 10...

Page 18: ...rred location 3 The hang rhe dosing pump oh pH close to the chamber and above the container of pH reductor 4 To put the electrodes in order of entry and exit carefully When the glue is dry 5 The recir...

Page 19: ...member to check the parameters of calcium hardness alkalinity TDS total dissolved solids pH and residual copper The more professionally monitored the better at least once a month depending on water lo...

Page 20: ...p water and gently dry especially the end part where the membrane is NOTE Clean and dry the pH probe before inserting it into the buffer solution 2 The membrane of the pH probe which is in the end sho...

Reviews: