42
Problem
Possible Solutions
11. DRAIN FLOWS CONTINUOUSLY
A. Foreign material in control
B. Internal control leak
C. Control valve jammed in brine or backwash position
D. Timer motor stopped or jammed teeth
E. Timer not operating properly
A. Remove piston assembly and inspect bore. Remove foreign material and check control in various regener-
ation positions
B. Replace seals and/or piston assembly
C. Replace piston and seals and spacers
D. Replace timer motor and check all gears for missing teeth
E. Replace timer
12. (Error Code) (Error E1) - Electrical Trouble Shooting:
Issue1:
When the controller is plugged, the buzzer beeps and the screen
displays ” System Error E1”
Cause:
The wire of micro switch is not plugged or loose.
Check the micro switch and connect the wire well.
13. (Error Code) (Error E1) - Electrical Trouble Shooting:
Issue 2:
The buzzer beeps and the screen displays “System Maintaining E1”
Cause:
The wire of micro switch is not plugged or loose..
Check the micro switch and connect the wire.
14. (Error Code) (Error E2) - Electrical Trouble Shooting:
Issue:
The buzzer beeps and the screen displays “System Error E2”
Cause:
The motor can not find its right position, micro switch or motor mal-
function, automatic circuit protection action.
Check the current of micro switch and motor.
15. (Error Code) (Error E2) - Electrical Trouble Shooting:
Issue 2:
The buzzer beeps and the screen displayed “ System Maintaining E2”
Cause:
The motor can not find its right position.
Replace Motor or PCB.
TROUBLE SHOOTING GUIDE
PRESS ‘+’ AND ‘-’ FOR 8 SECONDS
PRESS MENU KEY AND SCROLL TO ‘MAIN MENU’. THEN PRESS ‘SET’ TILL IT BEEPS. SCROLL TO
ADVANCED MENU
PRESS MENU KEY AND SCROLL TO ‘MAIN
MENU’. THEN PRESS ‘SET’ TILL IT BEEPS
VALVE SETTINGS
MODELS LANGUAGE
REGION
VALVE
METER
RATIO
SALT VS
EFFICIENCY
AUTO
CALCULATION
RESIN
VOLUME
REFILL
RATE
REGEN. MODE
BACKWASH
OVERRIDE
EMERGENCY
REGEN.
REGEN
CYCLES
BRINE /
RINSE
BACK
WASH
RINSE
REGEN TIME
SETTING
SALT MODE
SETTING
BRINE
PREFILL
SET
PREFILL Injector
Injector
Color
BLFC
Washer
DLFC
Washer
DLFC
Washer
Code
75
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
0.75CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#0000
Black 0.2 GPM 1.35
#7
100
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
1.0CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#0000
Black 0.2 GPM
2.0
#2
150
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
1.5CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#0000
Black 0.2 GPM
2.4
1S
200
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
2.0CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#00
Purple 0.2 GPM
3.5
2S
250
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
2.5CF 0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#00
Purple 0.2 GPM
4.0
3S
300
ENGLISH US GALLONS UPFLOW
1.234 DONT TOUCH
ON
3CF
0.2 GPM METER DELAY
OFF
ON
90
15
15
2:00AM STANDARD
ON
70%
#1
White 0.2 GPM
5.0
4S
Upflow Valve Programming (Models 89UF)
Below is how the settings are set at factory:
PRESS ‘+’ AND ‘-’ FOR 8 SECONDS
PRESS MENU KEY AND SCROLL TO ‘MAIN MENU’. THEN PRESS ‘SET’ TILL IT BEEPS. SCROLL
TO ADVANCED MENU
PRESS MENU KEY AND SCROLL TO
‘MAIN MENU’. THEN PRESS ‘SET’ TILL
IT BEEPS
VALVE SETTINGS
MODELS LANGUAGE
REGION
VALVE
METER
RATIO
SALT VS
EFFICIENCY
AUTO
CALCULATION
RESIN
VOLUME
REFILL
RATE
REGEN. MODE BACKWASH
OVERRIDE
EMERGENCY
REGEN.
REGEN
CYCLES
BACK WASH
DURATION
BRINE
DRAW
DURATION
RINSE
DURATION
REFILL
DURATION
REGEN
TIME
SETTING
REGEN
DAY
SETTING
SYSTEM
CAPACITY
SALT
MODE
SETTING
Injector Injector
Color
BLFC
Washer
DLFC
Washer
DLFC
Washer
Code
75
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
0.75CF 0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#1
White 0.7 GPM
1.4
#7
100
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
1.0CF 0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#1
White 0.7 GPM
2.0
#2
150
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
1.5CF 0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#1
White 0.7 GPM
2.4
1S
200
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
2.0CF 0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#2
Blue
0.7 GPM
3.5
2S
250
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
2.5CF 0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#2
Blue
0.7 GPM
4.0
3S
300
ENGLISH US GALLONS DOWNFLOW 1.393 DONT TOUCH
ON
3CF
0.7 GPM METER DELAY
OFF
OFF
10
60
10
N/A
2:00AM
N/A
N/A
STAN-
DARD
#3
Yellow 0.7 GPM
5.0
4S
Downflow Valve Programming (Models 89DF)
MASTER PROGRAMMING GUIDE
Summary of Contents for 89DF Series
Page 2: ......
Page 50: ......
Page 51: ......
Page 52: ...54577 11 18 TOLL FREE 1 877 288 9888 Regina SK Cambridge ON Carmel IN Pottstown PA Phoenix AZ...