30
31
Meter Cable
2X Clips
3.
2.
4.
5.
1.
Special Tool
Impeller
Remove
6X
screws
Meter
Support
Meter Cable
1.
2.
3.
4.
5.
2X Clips
METER ASSEMBLY REPLACEMENT
(For Models Manufactured after
Valve Serial # Date of November 2015)
1.
Disconnect the meter cable from the meter.
2.
Disconnect the valve from bypass by removing clips
3.
Remove the coupling adapter from the valve
4.
Remove the meter support and then the impeller out from the coupling and
clean it
5.
Replace meter with the help of special tool and re-assemble the
removed components back in the section
METER ASSEMBLY REPLACEMENT
(For Models Manufactured before
Valve Serial # Date of November 2015)
1.
Disconnect the meter cable from the meter.
2.
Disconnect the valve from bypass by removing clips
3.
Remove the coupling adapter from the valve
4.
Remove six screws and pull out the meter support and impeller.
5.
Replace meter with the help of special tool and re-assemble the removed
components back in the section