28
29
4.
IInstall the holder and the Res Care Solution
5.
Take off the small hole cover on the Brine
Well lid.
6.
Take off the cover of the Res care bottle . Insert the
wick, making sure it touches the bottom of the
bottle. Insert the other end of the tube completely
into the hole in the brine well cap. Automatic
feeding will start in a few hours.
Before Servicing
1.
Turn off water supply to conditioner :
a.
If the conditioner installation has a 3 valve bypass system first open the valve in the bypass line, then close the valves at the conditioner inlet & outlet.
b. If the conditioner has an integral bypass valve, put it in the bypass position.
c. If there is only a shut-off valve near the conditioner inlet, close it.
2.
Relieve water pressure in the conditioner by stepping the control into the backwash position momentarily. Return the control to the In Service position.
3.
Unplug Electrical Cord from outlet.
4.
Disconnect drain line connection.
SERVICING 89HE VALVE
CAUTION!
Disassembly while under
pressure can result in flooding.
Always follow these steps prior
to servicing the valve.
WARNING!
ELECTRICAL SHOCK
HAZARD!
UNPLUG THE UNIT
BEFORE REMOVING THE
COVER OR ACCESSING ANY
INTERNAL CONTROL PARTS