- 3 -
Normal operation
The control box automatically switches to normal operation once the initiating phase has elapsed,
whereby the individual actual operation sequences are shown in the display and by the LED lights.
The individual operation phases are shown optically. The below display monitoring is shown dur-
ing continuous operation.
LED
– light sequence
Display monitor
All 8 LED’s light successively (GREEN phase),
positive d.c. (approx. 100 V) is released to the
water part
Duration about 8 s
Monitoring of day, date and time
Operation state Monitoring current
The current ratings for the corresponding HY-
MAG
types are
shown in the below list
REFIT
®
– Phase
Duration about 2 s (magnetic remanence clear-
ing, LED extinguishes successively to the left
within 2 seconds
– GREEN LED)
All 8 LED’s light successively (RED), negative
d.c. (approx. 100 V) is released to the water part
Duration about 8 s
REFIT
®
– Phase
Duration about 2 s (magnetic remanence clear-
ing, LED extinguishes successively to the left
within 2 seconds
– RED LED)
The shown current rating is dependent on the type of water conditioning unit.
HY-
MAG
DN20 / DN25
235 mA ± 10%
HY-
MAG
DN32 / DN40
345 mA ± 10%
HY-
MAG
DN50 / DN65
465 mA ± 10%
Thu 11.10.2001 10:30
Cont. operation + xxx mA
Thu 11.10.2001 10:30
Cont. operation + 0mA
Thu 11.10.2001 10:30
Cont. operation - xxx mA
Thu 11.10.2001 10:30
Cont. operation - 0mA