- 4 - 

Menu sequences 

 
Input  and  programming  of  HY-

MAG

  Competition  control  box  by  pressing  the  front  foil  buttons 

(behind transparent cover) as below: 
 

 

 
 
 
 

Call up menu. 
Return from the individual menu levels.   

 
 
 
 

 
Clear parameters. 

 
 
 
 

Selection of individual menu sequences in menu levels, modification 
and setting of parameters.  

 
 
 
 

Selection of individual menu sequences in menu levels, modification 
and setting of parameters.  

 
 
 
 

 
Retrieval of individual menu sequences, confirmation/ acknowedge-
ment of settings  

 

 
NOTE: 

The monitoring returns to Standard Mode if input is delayed for more than 30 sec-
onds and standard operation is shown in the display. 

 

Main programme menu 

 
The individual sub-menus are selected in the main menu. The main menu is reached by pressing 

the button  

 once. 

 
 

The below menu sequences can be retrieved by the buttons  

  

 

 

Operation mode 

 
 
 

 

Operation hours 

 
 
 

 

Day / Time 

 
 
 

 

Time zones 

 
 
 

 

Language 

 
 
 

 

Service 

 
 

Main menu 
Operation mode 

Main menu 
Operation hours 

Main menu 
Day / Time 

Main menu 
Time zones 

Main menu 
Language 

Main menu 
Service 

Summary of Contents for HY-MAG Competition

Page 1: ...1 Operating Instruction HY MAG Competition Serial number _______________ HYDROTEC Hydrotec House 4 5 Manor Courtyard Hughenden Avenue High Wycombe HP13 5RE Tel 01494 796040 Fax 01494 796049...

Page 2: ...trol operations the plastic cover must be opened with the right hand closure Once setting has been finished the glass must be closed again with an audible noise Initiating phase Once the control box w...

Page 3: ...t ratings for the corresponding HY MAG types are shown in the below list REFIT Phase Duration about 2 s magnetic remanence clear ing LED extinguishes successively to the left within 2 seconds GREEN LE...

Page 4: ...Retrieval of individual menu sequences confirmation acknowedge ment of settings NOTE The monitoring returns to Standard Mode if input is delayed for more than 30 sec onds and standard operation is sho...

Page 5: ...can be selected by pressing the buttons and the correct mode then be confirmed and acknowledged by pressing the button once The control box and or monitoring returns automatically to main menu after...

Page 6: ...ed whereby the display shows the actual setting If the setting is to be altered press the button and should no modification be requested the sub menu can be left by pressing the button The active fiel...

Page 7: ...h a line underneath Once the correct setting is achieved the button must be pressed until the line underneath is no longer visible If the total switch settings for the selected and retrieved group of...

Page 8: ...ttons or Once the correct language is shown confirm by pressing the button and the setting is finished Service The service menu is code protected and can be retrieved from authorised service personnel...

Page 9: ...AC max breaking capacity 1500W class AC1 Ohm load max breaking capacity 300W class AC15 electro magnetic load min breaking capacity 500mW 12V 10mA Failure 1 Undercurrent Coil not closed faulty connect...

Page 10: ...rrect fit of Harting coupling Failure 2 Overload Failure at magnet coil in water unit Inform Hydrotec immediately in that case since there are no further local steps possible The first time the failur...

Reviews: