13
8 -
After allowing the glue joints to dry for 24-hours, a
STATIC
leak test must be performed. You can
accomplish this by
SLOWLY
filling the
tub with
COLD WATER
until the water level is at least 2”
above the highest jet.
IMPROPER INSTALLATION OF THE PURE HEAT HEATER CAN RESULT IN WATER LEAKING
FROM THE PLUMBING SYSTEM! WATER DAMAGE CAN OCCUR TO SPACES BELOW OR
ADJACENT TO THE HYDROMASSAGE BATHTUB.
Do not leave the tub unattended during the testing process and only fill the tub with enough water to
exceed the level of the hydromassage jets.
FILL THE TUB SLOWLY SO FILLING CAN BE STOPPED IF A LEAK IS DETECTED. DRAIN THE
TUB IMMEDIATELY IF A LEAK IS DETECTED AND CORRECT THE PROBLEM BEFORE
RETESTING.
9 -
If no leaks were detected, a
PRESSURE
leak test must be performed. Perform this final
REQUIRED
leak test by activating the hydromassage jet pump. Allow the system run for 15-20 minutes
minimum. The cold water will allow you to verify that the “Heater On” indicator is illuminated on your
Pure Heat heater. If the light does not illuminate or if you encounter any other problems, refer to the
Troubleshooting section of these instructions.
IF NO LEAKS WERE DETECTED AND YOU HAVE VERIFIED THAT
YOUR PURE HEAT HEATER IS FUNCTIONING PROPERLY,
CONGRATULATIONS, THE INSTALLATION OF YOUR PURE HEAT
HEATER IS COMPLETE. YOU CAN NOW RELAX AND ENJOY THE
COMFORT YOU WILL EXPERIENCE IN YOUR HEATED
HYDROMASSAGE BATHTUB.
TEST YOUR INSTALLATION
www.bathheaters.com