14
THERE ARE NO SERVICEABLE PARTS INSIDE HEATER - DO NOT OPEN
NOTHING WORKS!
Main Breaker is OFF - Set to On
GFCI Tripped - Press Reset
Power Cord not plugged in - Plug in power cord (if plugged in, is plug lit?)
HEATER “ON” LIGHT DOES NOT TURN ON
Overheat Protection Tripped - Power off, let cool, then power on
Power cord not plugged in - Plug in power cord (if plugged in, is plug lit?)
GFCI Tripped - Press Reset
No Power to Heater - Reset breaker at service panel
Pump Is Not Running - Activate hydromassage pump
Water Temperature Too High
HEATER “ON” LIGHT WILL NOT TURN OFF
Water Level Too Deep for Pressure Switch Setting - Lower Water Level
Pressure Switch Defective - Replace Heater
Heater Wiring Error - Replace Heater
OVERHEAT PROTECTION TRIPPED
Water Blockage - Correct/Remove Blockage
Low Water Flow - Correct Problem
High-Limit Will Not Reset - Replace Heater
WATER LEAKS FROM CONTROL BOX
Defective Component - Replace Heater
GFCI TRIPS OCCASIONALLY
Lightning or Electrical Storm, Power Surge, Extremely Humid Conditions or Radio Frequency
Interference - Reset GFCI Note: Assure Heater is Properly Grounded and Bonded
Inspect Heater for Leaks or Moisture - Correct or Replace as Required
GFCI TRIPS REPEATEDLY
Defective Component - Replace Heater
CIRCUIT BREAKER TRIPS
Breaker Size Improper - Contact a qualified service technician
Heater Requires a DEDICATED Circuit - Assure No Other Appliances are on this Circuit
TEMPERATURE NOT REACHING COMFORT ZONE
Designed to maintain bath water temperature and is not meant to heat water from cool or cold.